1500kVA AN 2100kVA AF Cast Coil Dry Type Transformer 13.2kV to 480Y/277V with IEC60076 Standard
| Brand Name: | WINLEY |
| Model Number: | SCB10-1500/13.2 |
| MOQ: | 1unit |
| Price: | $1000-$100000 |
| Packaging Details: | Plywood case |
| Payment Terms: | T/T |
Best for:
Protected indoor electrical rooms, transformer rooms, data center power rooms, commercial building service rooms, and industrial facility power rooms requiring oil-free 13.2kV to 480Y/277V step-down distribution.
Customizable Specifications:
kVA, primary voltage, secondary voltage, frequency, vector group, enclosure/IP requirement, cooling method, tap range, ambient condition, altitude, quantity, destination port and required accessories.
This 1500kVA AN / 2100kVA AF cast coil dry type transformer is designed for indoor medium-voltage step-down distribution from 13.2kV to 480Y/277V. It is suitable for transformer rooms, electrical rooms, data center power rooms, commercial building service rooms, industrial facility power rooms, and integrated power distribution systems.
With cast resin insulated coils, IP00 open type construction, AN/AF cooling, Dyn11 vector group, and five-position high-voltage tap adjustment, this transformer is built for projects requiring oil-free indoor power distribution and flexible integration into customer electrical rooms, enclosures, or packaged power systems. The 480Y/277V secondary output is suitable for downstream distribution panels, lighting systems, HVAC equipment, auxiliary loads, and facility power systems.
Product Photos
![]()
![]()
![]()
![]()
Main Data
| Item | Data |
|---|---|
| Product type | Cast coil dry type transformer |
| Rated capacity | 1500kVA OA / 2100kVA FA |
| Phase | 3 Phase |
| Primary voltage | 13,200V |
| Secondary voltage | 480Y/277V |
| HV tap voltages | 13,860 / 13,530 / 13,200 / 12,870 / 12,540V |
| Frequency | 60Hz |
| Vector group | Dyn11 |
| Insulation class | Class F |
| Temperature rise | 100K |
| Cooling method |
AN/AF |
| Climatic class | C2 |
| Environmental class | E2 |
| Fire class | F1 |
| No-load loss | 2,650.2W |
| Load loss | 12,708.8W at 120℃ |
| No-load current | 0.28% |
| Impedance | 6.01% at 120℃ |
| Dimensions | 1780 × 900 × 2103mm |
| Weight | 3430kg |
Technical drawings
![]()
Standard Features
-
Cast resin windings: Provide an oil-free insulation structure for indoor electrical rooms, building service rooms, equipment cabinets and integrated power systems.
-
F-class insulation with C2 / E2 / F1 rating: Supports indoor dry-type transformer projects where temperature rise, environmental class and fire behavior need to be considered.
-
1500kVA OA / 2100kVA FA capacity: Provides natural-air and fan-assisted capacity options for electrical room layouts, enclosure integration and load planning.
-
OA/FA cooling system: Natural air cooling with fan-assisted forced air cooling helps support additional heat dissipation when operating under fan-cooled capacity.
-
Temperature control system: Temperature monitoring and fan control arrangement help monitor winding temperature and support cooling operation during service.
-
Five-position high-voltage tap terminals: 13,860V / 13,530V / 13,200V / 12,870V / 12,540V tapping allows primary-side voltage adjustment during commissioning.
| Sector | Applications |
|---|---|
| Coastal or humid indoor projects | Medium-voltage step-down distribution for projects where environmental class needs to be considered, with installation inside an electrical room, enclosure or customer-provided cabinet. |
| Indoor electrical rooms | 13.2kV to 480Y/277V transformer installation for controlled electrical rooms, transformer rooms, switchgear rooms and building service areas. |
| Commercial building power systems | Power supply for 480Y/277V distribution panels, lighting systems, HVAC equipment, pumps, elevators and building auxiliary loads. |
| Data center power rooms | Indoor dry type transformer application for 480Y/277V power circuits, cooling equipment, auxiliary systems and electrical room integration. |
| Industrial equipment systems | Step-down power distribution for low-voltage panels, control systems, fans, pumps, compressors and production support loads. |
| Fire-sensitive indoor areas | Oil-free dry type transformer application for buildings or equipment rooms where liquid-filled transformers are not preferred. |
| Cabinet-integrated power systems | Transformer integration for packaged power systems, switchgear lineups, customer-provided enclosures and skid-mounted electrical systems. |
|
Rated capacity |
High Voltage |
Low |
Connection Symbol |
No-Load Loss |
On-Load Loss |
No Load Current |
Weight |
Dimension L*W*H(mm)
|
|
100 |
6 6.3 10 10.5 11 |
0.4 |
Dyn11 |
540 |
1990 |
2.4 |
520 |
1600*1300*2200 |
|
315 |
970 |
4080 |
1.8 |
1085 |
1800*1350*2200 |
|||
|
500 |
1350 |
5790 |
1.8 |
1520 |
2000*1400*2200 |
|||
|
630 |
1530 |
6840 |
1.6 |
1820 |
2000*1400*2200 |
|||
|
1000 |
2070 |
9780 |
1.4 |
2550 |
2450*1450*2200 |
|||
|
1250 |
2380 |
11500 |
1.4 |
2900 |
2300*1500*2200 |
|||
|
1600 |
2790 |
13800 |
1.4 |
3490 |
2400*1550*2200 |
|||
|
2000 |
3240 |
16300 |
1.2 |
4220 |
2600*1600*2200 |
|||
|
2500 |
3870 |
19300 |
1.2 |
4955 |
2600*1600*2200 |
![]()