logo
Good price  online

products details

Home > Products >
Cast Coil Transformer
>
1250Kva Cast Resin Dry Type Transformers Isolation 480V IEEE ANSI Standard

1250Kva Cast Resin Dry Type Transformers Isolation 480V IEEE ANSI Standard

Brand Name: WINLEY
Model Number: SCB10-1250/0.48
MOQ: 1unit
Price: $5000-$100000
Packaging Details: Plywood case
Payment Terms: T/T
Detail Information
Place of Origin:
CHINA
Certification:
CE,ISO
Type:
Cast Coil Isolation Transformer
Rated Capacity:
1250
Primary Voltage:
480V
Secondary Voltage:
480Y/277
Cooling Method:
AN/AF
Insulation Class:
F (155℃)
Temperature Rise:
100℃
Standard:
IEEE ANSI C57.12.00
Supply Ability:
1000set/month
Product Description

 

1250Kva Cast Resin Dry Type Transformers Isolation 480V IEEE ANSI Standard
 
 
Cast-resin transformers are units with windings completely vacuum cast in epoxy resin. The epoxy provides both mechanical strength and protection from the environment.
 
Product Photos
 
 1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 0  1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 1

 

 1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 2  1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 3
 
Main data
 

No. Item Unit Reqirement
1 Type ~ dry type cast resin
2 Rated capacity kVA 1250
3 No. of Phase ~ 3
4 Primary Voltage V 480
5 Primary bushing ~ (3) 4-hole spade
6 Secondary Voltage V 480Y/277
7 Secondary bushing   (4) 4-hole spade
8 Cooling method ~ AN/AF
9 Rated frequency Hz 60
10 Vector group ~ Dyn1
11 Insulation class ~ F (155)
12 Temperature rise K 100
13 Impedance % 4.5~6.0
14 Winding material ~ Copper/Copper
15 Core material ~ silicon steel
16 Over heat protection ~ temperature controller with cooling fans
21 Enclosure ~ coated steel, NEMA 3R enclosure

 

Dry transformer features


1)Moisture-proof and corrosion-resistant ability , and it can run normally at 100%humidity,especially for work in extreme environmental conditions.
2)Lost loss, small local discharge, small noise, and strong heat dissipation capacity, can run 150%of the rated load operation.
3)High the whole mechanical strength of the cast coil withstand sudden short -circuit capability.
4)Safe, fire prevention, no pollution, can be installed directly in the load center.
5)Simple maintenance and installation, low comprehensive operating costs.


Technical drawings
 
1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 4
 


Production process
 

High-voltage winding appliesvacuumpouring of padding epoxyresin which, at highlevel,reduces partial discharge capacity andelevates the electric strength of coils. The insideand outside of the winding is buildup with glassfiber grid overlaywhich strengthens thethemechanicalrobustnessandimprovesresistance of short-circuits and ensures the coilswill never crack.
 

Low-voltage winding applies the structure that windedby copper foil which solves the problem that the axle wouldpoint to the helix angle when winds and make the ampereturn of winding distribute evenly. Meanwhile, the coilsapplies axial fan which improves the heat dispersion.Between the layers of winding, it applies DMD epoxy resinpreliminary dip cloth and makes it whole solidificationfor


1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 5

 

Performance & Advantages — WINLEY Cast Coil Transformer

 

Our cast coil transformers are engineered for durability and high performance across power-system applications. Key advantages:

 

  • Short-time overload capability: Resin-encapsulated windings provide better resistance to sudden power surges than oil-filled designs.
  • Visible temperature monitoring: Built-in winding temperature probes display readings on a digital screen for real‑time status.
  • Low maintenance: Compact design generally requires only routine inspections and simple cleaning.
  • Low noise: Quiet operation suits noise-sensitive environments.
  • Low fire risk: Self‑extinguishing materials significantly reduce fire hazard compared with conventional types.
  • Environmentally friendly: Constructed with materials that meet modern environmental and safety standards.
  • Low installation cost: Easy to install and can be placed closer to the load, reducing time and expense.
  • Moisture resistant: Resistant to humidity and atmospheric contaminants; suitable for outdoor or high‑humidity locations.
  • High-impact loading: Robust construction withstands heavy impact loads in industrial settings.
  • Vibration tolerant: Select models operate reliably under heavy vibration conditions.

1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 6

1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 7

High-voltage winding appliesvacuumpouring of padding epoxyresin which, at highlevel,reduces partial discharge capacity andelevates the electric strength of coils. The insideand outside of the winding is buildup with glassfiber grid overlaywhich strengthens thethemechanicalrobustnessandimprovesresistance of short-circuits and ensures the coilswill never crack.
 

Low-voltage winding applies the structure that windedby copper foil which solves the problem that the axle wouldpoint to the helix angle when winds and make the ampereturn of winding distribute evenly. Meanwhile, the coilsapplies axial fan which improves the heat dispersion.Between the layers of winding, it applies DMD epoxy resinpreliminary dip cloth and makes it whole solidificationfor

Good price  online

Products Details

Home > Products >
Cast Coil Transformer
>
1250Kva Cast Resin Dry Type Transformers Isolation 480V IEEE ANSI Standard

1250Kva Cast Resin Dry Type Transformers Isolation 480V IEEE ANSI Standard

Brand Name: WINLEY
Model Number: SCB10-1250/0.48
MOQ: 1unit
Price: $5000-$100000
Packaging Details: Plywood case
Payment Terms: T/T
Detail Information
Place of Origin:
CHINA
Brand Name:
WINLEY
Certification:
CE,ISO
Model Number:
SCB10-1250/0.48
Type:
Cast Coil Isolation Transformer
Rated Capacity:
1250
Primary Voltage:
480V
Secondary Voltage:
480Y/277
Cooling Method:
AN/AF
Insulation Class:
F (155℃)
Temperature Rise:
100℃
Standard:
IEEE ANSI C57.12.00
Minimum Order Quantity:
1unit
Price:
$5000-$100000
Packaging Details:
Plywood case
Delivery Time:
30days
Payment Terms:
T/T
Supply Ability:
1000set/month
Product Description

 

1250Kva Cast Resin Dry Type Transformers Isolation 480V IEEE ANSI Standard
 
 
Cast-resin transformers are units with windings completely vacuum cast in epoxy resin. The epoxy provides both mechanical strength and protection from the environment.
 
Product Photos
 
 1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 0  1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 1

 

 1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 2  1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 3
 
Main data
 

No. Item Unit Reqirement
1 Type ~ dry type cast resin
2 Rated capacity kVA 1250
3 No. of Phase ~ 3
4 Primary Voltage V 480
5 Primary bushing ~ (3) 4-hole spade
6 Secondary Voltage V 480Y/277
7 Secondary bushing   (4) 4-hole spade
8 Cooling method ~ AN/AF
9 Rated frequency Hz 60
10 Vector group ~ Dyn1
11 Insulation class ~ F (155)
12 Temperature rise K 100
13 Impedance % 4.5~6.0
14 Winding material ~ Copper/Copper
15 Core material ~ silicon steel
16 Over heat protection ~ temperature controller with cooling fans
21 Enclosure ~ coated steel, NEMA 3R enclosure

 

Dry transformer features


1)Moisture-proof and corrosion-resistant ability , and it can run normally at 100%humidity,especially for work in extreme environmental conditions.
2)Lost loss, small local discharge, small noise, and strong heat dissipation capacity, can run 150%of the rated load operation.
3)High the whole mechanical strength of the cast coil withstand sudden short -circuit capability.
4)Safe, fire prevention, no pollution, can be installed directly in the load center.
5)Simple maintenance and installation, low comprehensive operating costs.


Technical drawings
 
1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 4
 


Production process
 

High-voltage winding appliesvacuumpouring of padding epoxyresin which, at highlevel,reduces partial discharge capacity andelevates the electric strength of coils. The insideand outside of the winding is buildup with glassfiber grid overlaywhich strengthens thethemechanicalrobustnessandimprovesresistance of short-circuits and ensures the coilswill never crack.
 

Low-voltage winding applies the structure that windedby copper foil which solves the problem that the axle wouldpoint to the helix angle when winds and make the ampereturn of winding distribute evenly. Meanwhile, the coilsapplies axial fan which improves the heat dispersion.Between the layers of winding, it applies DMD epoxy resinpreliminary dip cloth and makes it whole solidificationfor


1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 5

 

Performance & Advantages — WINLEY Cast Coil Transformer

 

Our cast coil transformers are engineered for durability and high performance across power-system applications. Key advantages:

 

  • Short-time overload capability: Resin-encapsulated windings provide better resistance to sudden power surges than oil-filled designs.
  • Visible temperature monitoring: Built-in winding temperature probes display readings on a digital screen for real‑time status.
  • Low maintenance: Compact design generally requires only routine inspections and simple cleaning.
  • Low noise: Quiet operation suits noise-sensitive environments.
  • Low fire risk: Self‑extinguishing materials significantly reduce fire hazard compared with conventional types.
  • Environmentally friendly: Constructed with materials that meet modern environmental and safety standards.
  • Low installation cost: Easy to install and can be placed closer to the load, reducing time and expense.
  • Moisture resistant: Resistant to humidity and atmospheric contaminants; suitable for outdoor or high‑humidity locations.
  • High-impact loading: Robust construction withstands heavy impact loads in industrial settings.
  • Vibration tolerant: Select models operate reliably under heavy vibration conditions.

1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 6

1250Kva  Cast Resin Dry Type Transformers  Isolation 480V IEEE ANSI Standard 7

High-voltage winding appliesvacuumpouring of padding epoxyresin which, at highlevel,reduces partial discharge capacity andelevates the electric strength of coils. The insideand outside of the winding is buildup with glassfiber grid overlaywhich strengthens thethemechanicalrobustnessandimprovesresistance of short-circuits and ensures the coilswill never crack.
 

Low-voltage winding applies the structure that windedby copper foil which solves the problem that the axle wouldpoint to the helix angle when winds and make the ampereturn of winding distribute evenly. Meanwhile, the coilsapplies axial fan which improves the heat dispersion.Between the layers of winding, it applies DMD epoxy resinpreliminary dip cloth and makes it whole solidificationfor