logo
Good price  online

products details

Home > Products >
Substation Power Transformer
>
7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards
Detail Information
Place of Origin:
CHINA
Certification:
ISO CE
Capacity:
7500/10000kVA
Primary Voltage:
13800V
Secondary Voltage:
7200Y/4160V And 4160Y/2400V
Cooling Class:
KNAN/KNAF
Standard:
ANSI IEEE
Winding Material:
Copper
Vector Group:
Dyn1yn1
Delivery Time:
90days
Supply Ability:
100set/month
Product Description
7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards
Product Overview

Designed for mobile, utility and industrial distribution projects, this three phase sealed substation power transformer provides two medium-voltage output circuits from a 13800V primary source. The unit is rated 7500 kVA under KNAN cooling and 10000 kVA under KNAF cooling, with dual outputs of 7200Y/4160V and 4160Y/2400V for separate 5000/6650 kVA and 2500/3350 kVA load groups. Copper windings, silicon-steel core construction, Midel 7131 synthetic ester fluid, off-circuit taps and a full monitoring/protection package support specification matching, outdoor installation and project review.


Why Choose Us

1.  With extensive experience in North American projects, Winley Electric designs substation transformers to meet applicable ANSI/IEEE, CSA, NEMA and related standard requirements.
2. With a stable supply chain, mature production processes, Winley Electric can deliver substation power transformers within 12 weeks after technical confirmation.
3. Winley Electric provides complete English technical documentation, 24/7 technical response, spare parts support, and a 2-year warranty to support project installation and long-term operation.


Product photos
 
7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 0

7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 1

Qualitrol 910-FLA-T-NO-STD Rapid Pressure Rise Relay

7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 2

Qualitrol 208-007-03-CN-T Pressure Relief Device

7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 3


Main Data


Item Data
Product type Three phase, dual secondary liquid immersed substation power transformer
Rated capacity 7500kVA KNAN / 10000kVA KNAF
Phase 3
Primary voltage 13,800V
Secondary voltage 7200Y/4160V and 4160Y/2400V
Frequency 60 Hz
Vector group Dyn1yn1
HV BIL / LV BIL 95kV / 60kV
Cooling method KNAN/KNAF
Winding material Copper
Temperature rise 65K
No-load loss 6128W
Load loss 40610W at 85°C
Impedance 5.72%
Dimensions 130 x 107 x 96 in
Weight 32,350 lb



Technical drawings


7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 4



Product Highlights


  • Dual-secondary voltage architecture
    One 13800V delta primary supplies both 7200Y/4160V and 4160Y/2400V secondary systems, allowing one transformer to support two medium-voltage distribution levels.
    7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 5


  • Defined split-load capacity
    The split secondary windings provide 5000/6650 kVA and 2500/3350 kVA under KNAN/KNAF operation, giving engineers a clear basis for downstream load planning.

  • KNAN/KNAF cooling flexibility
    The transformer operates at 7500 kVA under KNAN natural cooling and reaches 10000 kVA when the cooling fan assembly is operating in KNAF mode.
    7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 6


  • Qualitrol pressure-protection package
    The Qualitrol rapid pressure rise relay detects sudden internal pressure changes and provides alarm or trip contacts. The Qualitrol pressure relief device helps release excessive tank pressure and improve transformer protection.7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 7



Standard Features


  • Qualitrol Rapid Pressure Rise Relay: Detects rapid internal pressure rise and sends an alarm or trip signal.
  • Qualitrol Pressure Relief Device: Releases excess internal pressure to protect the transformer tank.
  • Oil Level Indicator: Displays the transformer oil level inside the tank.
  • Nameplate: Displays key ratings and identification information.
  • Temperature Controller: Monitors winding temperature and controls alarms, trips or cooling fans.
  • Thermowell Housing: Houses the temperature sensor for monitoring transformer oil temperature.
  • Terminal Box: Houses electrical terminals and connection components.
  • Cooling Fan Assembly: Forces air through the radiator to improve cooling.
  • Pressure Indicator: Shows the internal tank pressure for safe operation monitoring.
  • Tap Changer: Adjusts winding taps to regulate the output voltage.
  • Oil Temperature Indicator: Monitors the transformer top-oil temperature.
  • Radiator Butterfly Valve: Isolates the radiator oil circuit during maintenance.


7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 8



Applications


Sector Suitable applications
Mobile substations Truck- or trailer-mounted power systems
Utility distribution Distribution points requiring two medium-voltage buses
Industrial facilities Plants with multiple medium-voltage motor, process or auxiliary buses
Infrastructure campuses Large facilities with separate medium-voltage distribution zones


7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 9



Factory Test Report


7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 10    7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 11



Substation Transformer Specification


kVA HV LV Width (mm) Length (mm) Height (mm)
315 kVA 11000V 400V 800 696 1336
500 kVA 27600V 480GrdY/277V 1730 2300 1510
500 kVA 11000V 415V 1700 1700 1650
750 kVA 11000V 433V 1850 1845 1465
1000 kVA 14400V 415/240V 1085 1860 1570
1200 kVA 13800V 240V 2450 1850 1820
1500 kVA 24940V 600V 1800 1880 1895
2000 kVA 7200V 600GrdY/346V 1766 2680 1982
2000 kVA 44000V 600V 1260 2090 1700
2500 kVA 24940V 480GrdY/277V 2400 2200 2060
3000 kVA 11000V 415V 1600 2330 1920
3000 kVA 22800V 415/240V 2130 3500 1910
3750 kVA 44000V 600V 2240 2650 2700
4000 kVA 33kV 600Y/347V 2150 3250 2290
5000 kVA 34500V 7200V 3780 1850 3450
5000 kVA 34500V 4160V 2799 2400 2938
6300 kVA 35000V 400V 3520 2820 3470
6800 kVA 34500V 800V 3400 2670 3400
7500 kVA 27600Y 4160V 3350 3290 2270


Substation transformer in industrial setting


 

Production Process


7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 13



7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 14


More Products



7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 15                     7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 16                      7500/10000kVA Three Phase Substation Power Transformer Dual Secondary 13800V to 7200Y/4160V & 4160Y/2400V Outdoor Mobile Configuration ANSI IEEE Standards 17