Pole Mounted Transformer
>
100kVA Single Phase Pole Mounted Transformer 34500V to 120/240V Double Bushing Primary ANSI/IEEE DOE Standards
Detail Information
Place of Origin:
CHINA
Certification:
UL,cUL
Type:
Overhead Distribution Transformer
Phase:
Single Phase
Capacity:
100kVA
Primary Voltage:
34500V
Secondary Voltage:
120/240V
Cooling Class:
ONAN
Winding Material:
Cooper
Standard:
Meets DOE 2016 ANSI IEEE Standards
Delivery Time:
30days
Supply Ability:
500set/month
Product Description
100kVA Single Phase Pole Mounted Transformer 34500V to 120/240V Double Bushing Primary ANSI/IEEE DOE Standards

Best for:

Suitable for Utility, rural, commercial and light industrial overhead distribution projects requiring 34500V to 120/240V step-down service.


Customizable Specifications:

kVA, primary voltage, secondary voltage, frequency, vector group / phasor, feed type, standard, accessories, destination port.


Product Overview

This 100kVA single phase pole mounted transformer is suitable for utility distribution points, rural overhead service, commercial power supply and outdoor distribution networks requiring medium-voltage step-down service. It is configured for 34500V to 120/240V operation, with ONAN cooling, mineral oil insulation and pole mounting via hanger brackets.

The double bushing primary arrangement, 200/30kV BIL rating, 5-position ±2.5% tap changer, copper windings and ANSI/IEEE C57.12.20 compliance help support specification review, installation planning and project-level voltage matching. For buyers working on overhead distribution or replacement transformer projects, this unit provides clear electrical data and project-ready configuration for inquiry and technical confirmation.



Product Photos


100kVA Single Phase Pole Mounted Transformer 34500V to 120/240V Double Bushing Primary ANSI/IEEE DOE Standards 0     100kVA Single Phase Pole Mounted Transformer 34500V to 120/240V Double Bushing Primary ANSI/IEEE DOE Standards 1


100kVA Single Phase Pole Mounted Transformer 34500V to 120/240V Double Bushing Primary ANSI/IEEE DOE Standards 2     100kVA Single Phase Pole Mounted Transformer 34500V to 120/240V Double Bushing Primary ANSI/IEEE DOE Standards 3



Main Data


Item Data
Product type Single phase pole mounted transformer
Rated capacity 100kVA
Phase Single phase
Primary voltage 34500V
Secondary voltage 120/240V
Frequency 60Hz
Cooling method ONAN
Winding material Copper
Temperature rise 65°C
No-load loss 190.3W
Load loss 767.7W at 85°C
Impedance 3%
Dimensions 30.3" W × 34.3" D × 51.7" H
Total mass 1590 lbs



Technical drawings


100kVA Single Phase Pole Mounted Transformer 34500V to 120/240V Double Bushing Primary ANSI/IEEE DOE Standards 4



Product Highlights

  • 5-Position Tap Changer
    The 5-position tap changer with 2.5% steps supports voltage adjustment during specification matching, site voltage review and commissioning preparation.
  • Double Bushing Primary Design
    The double bushing primary arrangement helps match common overhead line connection requirements and supports project layouts where primary line connection flexibility is needed.
  • Project-Ready Accessories
    Grounding provisions, lifting lugs, automatic pressure relief device, fill valve, drain valve with sampler and H1 lightning arrestor help support installation, handling and field maintenance requirements.

100kVA Single Phase Pole Mounted Transformer 34500V to 120/240V Double Bushing Primary ANSI/IEEE DOE Standards 5


Applications

Sector Suitable applications
Utility Distribution Utility distribution points and overhead service drops
Rural Overhead Distribution Rural homes, remote buildings and small community service points
Agricultural Power Supply Farms, barns, irrigation controls and agricultural auxiliary loads
Commercial Power Supply Small shops, roadside facilities and service buildings
Light Industrial Facilities Small workshops, utility-owned auxiliary loads and outdoor equipment service
Outdoor Distribution Networks Pole-line distribution, remote infrastructure and field service points



Specification

Rated Capacity (kVA) High Voltage (kV) No Load Loss (W) On Load Loss (W) Height (mm) Depth (mm) Width (mm) Weight (kg)
15kVA

34.5/19.92 13.8/7.96 13.2/7.6 12.47/7.2

 or others

50 195 840 740 610 294
25kVA 80 290 840 740 610 362
37.5kVA 106 360 840 760 610 476
50kVA 135 500 840 810 610 553
75kVA 190 650 840 860 610 672
100kVA 280 1010 910 1200 965 714
167kVA 435 1530 1000 1200 965 913
250kVA 550 2230 1250 1300 1430 1106