167kVA Single Phase Pole Mounted Transformer 34500/19920V to 120/240V for Rural Distribution
Detail Information
Place of Origin:
CHINA
Certification:
UL, cUL
Type:
Conventional Single-Phase Pole-Mounted Distribution Transformer
Capacity:
167kVA
Primary Voltage:
24940Y/14400V
Secondary Voltage:
120/240V
Winding Material:
Copper
Frequency:
60Hz
Cooling Class:
ONAN
Standard:
ANSI/IEEE
Delivery Time:
30 days
Supply Ability:
500set/month
Product Description
167kVA Single Phase Pole Mounted Transformer 34500/19920V to 120/240V for Rural Distribution
Why Choose US
  • UL and cUL Listed Product Range

Our pole-mounted distribution transformer range from 10kVA to 500kVA is UL and cUL Listed under File No. E543292. Products are designed to meet or exceed applicable ANSI/IEEE, CSA, DOE 2016, and IEC 60076 requirements.

  • Flexible Project Customization

Each transformer can be configured around project-specific voltage, capacity, protection, connection, and installation requirements. Customer-specified accessory brands, including Eaton Cooper Power series and Qualitrol, are also available upon request.

  • Global Supply and Technical Support

With products supplied across North America, South America, and Southeast Asia, Winley Electric combines decades of transformer experience with responsive technical support. From specification review to final delivery, we provide safe, reliable, and efficient transformer solutions for utility and industrial projects.

167kVA Single Phase Pole Mounted Transformer 34500/19920V to 120/240V for Rural Distribution

Product Overview

This 167 kVA single-phase pole mounted distribution transformer converts primary voltage to secondary voltage from 34500V to 120/240V for residential, commercial, and rural overhead utility grids. Built in full compliance with ANSI C57.12.20 and DOE 2016 efficiency standards, this unit provides long-term voltage regulation and step-down reliability in demanding outdoor environments via standard ANSI Type B pole hanger brackets.

Engineered with 100% copper windings and a high 200 kV BIL insulation rating, this transformer delivers superior thermal performance and exceptional lightning surge resistance. This robust construction prevents grid disruptions during peak electrical loads and severe weather events, making it an ideal asset for utility contractors seeking maintenance-free grid durability.

Product Display
167kVA Single Phase Pole Mounted Transformer 34500/19920V to 120/240V for Rural Distribution     167kVA Single Phase Pole Mounted Transformer 34500/19920V to 120/240V for Rural Distribution     
Main Data
Electrical Ratings
Specification Data Specification Data
Product Type Conventional Single-Phase Pole-Mounted Distribution Transformer Model D11-167/34.5/0.12-0.24
Rated Capacity 167kVA Phase Single Phase
Primary Voltage 34500GrdY/19920V Secondary Voltage 120/240V
HV BIL 200kV LV BIL 30kV
Frequency 60Hz Insulation Class Class E, 120°C
Connection Symbol Ii0 Temperature Rise 65°C
Construction & Installation
Specification Data Specification Data
Cooling Method ONAN Insulating Liquid Mineral Oil, Non-PCB
Winding Material Copper Core Material Grain-Oriented Steel
Dimensions 40.4"W × 35.6"D × 59.5"H Total Weight 2041lb
Ambient Temperature -40°C to +50°C Elevation 5,910ft
Wind Speed Rating 100mph Sound Level 55dBA
Factory-Tested Performance
Test Item Tested Value Test Item Tested Value
No-Load Loss 207.3W Load Loss at 85°C 1573.2W
Impedance at 85°C 4.36% No-Load Current 0.12%
Technical drawings
167kVA Single Phase Pole Mounted Transformer 34500/19920V to 120/240V for Rural Distribution
Standard Features
  • High-Voltage Porcelain Bushing

    Top-cover mounted porcelain bushing with mechanical terminal connection for #8 to #2 AWG primary incoming lines, rated for 200 kV BIL.

  • 4-Hole Low-Voltage Spade Bushings

    Side-mounted secondary bushings with 4-hole tin-plated copper spades suitable for 2/0 to 1000 MCM copper or aluminum conductors.

  • Automatic Pressure Relief Valve (YSF-0.03)

    Preserves tank pressure integrity by automatically releasing internal gas when pressure exceeds 0.03 ± 0.01 MPa.

  • 5-Position External Tap Changer Switch

    Side-tank mounted rotary switch providing ±5% voltage regulation (Taps 1–5) via an easy-to-use external handle.

  • Copper Tank Grounding Strap & Bosses

    Ensures solid equipment grounding with a 0.3mm copper ground strap and stainless steel grounding bosses.

  • ANSI Type B Pole Mount Hanger Brackets

    Heavy-duty steel mounting brackets pre-welded to the tank wall for simple, safe hanging on utility power poles.

  • Oil Drain Valve & Internal Level Indicator

    Includes a 1/2" NPT drain plug for easy fluid sampling/maintenance and an internal oil mark for quick visual confirmation.

167kVA Single Phase Pole Mounted Transformer 34500/19920V to 120/240V for Rural Distribution

Applications
  • Rural Utility Feeders

Ideal for stepping 34.5kV-class grounded-wye overhead distribution down to 120/240V for dispersed rural customers.

  • Residential Distribution

Suitable for utility pole installations supplying 120/240V split-phase power to residential neighborhoods and housing developments.

  • Agricultural & Remote Commercial Loads

Provides 167kVA single-phase capacity for farms, pumping facilities, workshops, roadside facilities, and other dispersed loads.

  • 34.5kV Overhead Distribution Extensions

Supports overhead feeder extensions where utilities require a conventional pole-mounted transformer with external protection coordination.

167kVA Single Phase Pole Mounted Transformer 34500/19920V to 120/240V for Rural Distribution

Specification
Rated Capacity (kVA) High Voltage (kV) No Load Loss (W) On Load Loss (W) Height (mm) Depth (mm) Width (mm) Weight (kg)
15kVA

34.5/19.92

13.8/7.96

13.2/7.6

12.47/7.2

or others

50 195 840 740 610 294
25kVA 80 290 840 740 610 362
37.5kVA 106 360 840 760 610 476
50kVA 135 500 840 810 610 553
75kVA 190 650 840 860 610 672
100kVA 280 1010 910 1200 965 714
167kVA 435 1530 1000 1200 965 913
250kVA 550 2230 1250 1300 1430 1106
Production process
167kVA Single Phase Pole Mounted Transformer 34500/19920V to 120/240V for Rural Distribution
FAQ:
Q1: What is the standard lead time?

A: Winley delivers standard pole-mounted distribution transformers within 30 days after technical approval. We provide a detailed production schedule and real-time manufacturing photos to help track progress.

Q2: How soon can I get a quotation, and what is the MOQ?

A: We offer a flexible MOQ of just 1 unit. Complete inquiries are quoted within 1–2 days with 24/7 support, we ensure highly cost-effective and reliable solutions.

Q3: Is OEM/ODM available?

A: Yes. We accept OEM and ODM. Winley pole-mounted distribution transformers are available in standard ratings from 15-333 kVA (and maximum capability up to 500kVA), with HV systems up to 34.5 kV. According to customer drawings, we can customize secondary voltage, conventional or CSP design, copper or aluminum windings, low-carbon steel or stainless-steel tanks, tap changers, surge arresters, secondary circuit breakers, meter sockets and custom colors. We also integrate components from brands such as Qualitrol and Eaton Cooper.

Q4: Do you provide UL/cUL and ANSI/IEEE support?

A: Yes. Our full range of products are UL/cUL-certified under UL File No. E543292, designed strictly in compliance with ANSI/IEEE, CSA, DOE, NEMA and IEC 60076 to meet grid connection and regulatory standards.

Q5: What documents can you provide for project approval?

A: We deliver a complete compliance package: approval drawings, datasheets, nameplate drawings, routine test reports, UL/cUL certs, DOE 2016 docs and accessory manuals. We also back your project with lifetime documentation support.

Q6: How do you ensure product quality?

A: Winley ensures quality through 4 annual unannounced UL audits and strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).

Q7: How long is the warranty?

A: 24 months from B/L. During the warranty period, If there are any accessory problems, just provide photos of damaged accessory, then we will provide free service. According to the number of products, we will provide easily damaged accessories for free. We can also provide technical support if you need.

Q8: Can you support replacement projects?

A: Yes. Winley matches existing nameplates, utility specifications, mounting dimensions and protection configurations for replacement projects.