300kVA Cast Coil Dry Type Distribution Transformer 12470Y/7200V to 480Y/277V ANSI/IEEE DOE Standards
Informations détaillées
Lieu d'origine:
Chine
taper:
Type sec, transformateur en résine coulée
Phase:
Triphasé
Capacité:
300kVA
Tension primaire:
12470Y/7200V
Tension secondaire:
480Y/277V
Classe de refroidissement:
UN
Augmentation de la température:
80k
Standard:
ANSI/IEEE
Délai de livraison:
30 JOURS
Capacité d'approvisionnement:
500set/mois
Description du produit
300kVA Cast Coil Dry Type Distribution Transformer 12470Y/7200V to 480Y/277V ANSI/IEEE DOE Standards

Product Overview


This 300kVA cast resin dry type distribution transformer is suitable for outdoor commercial buildings, utility distribution points, light industrial facilities, and site power systems that require 480Y/277V service from a 12.47kV class primary feeder.


The transformer is configured for 12470Y/7200V to 480Y/277V, three-phase, grounded-wye to grounded-wye operation, with YNyn0 vector group, 95kV HV BIL, 30kV LV BIL, 5-position HV taps, terminal-lug connections, and primary 40E fused overcurrent protection.


With a NEMA 3R coated steel enclosure, ANSI 61 grey epoxy finish, pad/floor mount structure, removable access doors, temperature monitoring, and space heaters with humidistat control, the unit supports specification review for outdoor distribution projects where enclosure protection, service access, and voltage matching are key purchasing considerations.



Why Choose US


1. Winley Electric manufactures cast resin transformers up to 10 MVA and 35 kV, designed in accordance with applicable ANSI/IEEE, AS 60076, IEC 60076 and related dry-type transformer standards.
2. Winley Electric cast resin transformers are engineered for demanding applications, offering high overload capability, low maintenance needs, strong mechanical strength, and reliable short-circuit withstand performance.
3. Winley Electric has extensive experience in cast resin transformer projects and can tailor product designs for solar PV, data centers, and other applications, including dual-split winding designs, multi-tap designs, and other customized electrical configurations.



Product Photos 


300kVA Cast Coil Dry Type Distribution Transformer 12470Y/7200V to 480Y/277V ANSI/IEEE DOE Standards 0


300kVA Cast Coil Dry Type Distribution Transformer 12470Y/7200V to 480Y/277V ANSI/IEEE DOE Standards 1


300kVA Cast Coil Dry Type Distribution Transformer 12470Y/7200V to 480Y/277V ANSI/IEEE DOE Standards 2



Main Data


Item Data
Product type Cast Resin Dry Type Distribution Transformer
Rated capacity 300kVA
Phase Three phase
Primary voltage 12470Y/7200V
Secondary voltage 480Y/277V
Frequency 60Hz
Vector group YNyn0
HV BIL / LV BIL 95kV / 30kV
Cooling method AN
Insulation class Class F, 155°C
Temperature rise 80°C
Winding material Aluminum
Ambient temperature rating 40°C
Altitude rating 1000m
Sound level 56dBA
No-load loss 603W
Load loss 2,856W
Impedance 5.42%
Reported efficiency 99.00%
Dimensions 71L × 59W × 75H in
Total mass 3,779lbs



Technical drawings

300kVA Cast Coil Dry Type Distribution Transformer 12470Y/7200V to 480Y/277V ANSI/IEEE DOE Standards 3



Standard Features

  • Metal enclosure cabinet
    Provides external protection for the transformer body and supports outdoor pad or floor installation.

  • Front and rear removable access doors
    Allow easier access for wiring inspection, cleaning, maintenance, and component replacement.

  • Ventilation louvers and door-mounted fans
    Improve air circulation inside the enclosure and help discharge heat from the transformer compartment.

  • Transparent protective barrier
    Separates live parts from the access area while allowing visual inspection of internal connections.

  • Cast resin coil assembly
    Forms the main winding structure and completes the voltage conversion inside the transformer.

  • HV/LV terminals with copper busbars and terminal lugs
    Provide connection points for incoming primary cables and outgoing secondary distribution circuits.

  • Primary fuses
    Provide primary-side overcurrent protection and support transformer protection coordination.

  • Temperature and humidity control components
    Include coil temperature sensors, digital temperature monitor, alarm/trip indication, space heaters, and humidistat control for monitoring and enclosure environment control.

300kVA Cast Coil Dry Type Distribution Transformer 12470Y/7200V to 480Y/277V ANSI/IEEE DOE Standards 4



Applications

Sector Suitable applications
Utility distribution Local distribution points, service entrance step-down, outdoor distribution nodes
Commercial facilities Retail centers, office buildings, schools, service buildings
Light industrial facilities Workshops, small manufacturing sites, process support loads
Outdoor distribution networks Site power systems, campus distribution, equipment yards
Infrastructure projects Pump stations, municipal facilities, utility service cabinets


Specification

Rated capacity
(KVA)

High Voltage
(KV)

Low
Voltage
(KV)

Connection Symbol

No-Load Loss
(W)

On-Load Loss
(W)

No Load Current
(%)

Weight
(KG)

Dimension 

L*W*H(mm)

 

100




6

6.3

10

10.5

11






0.4





Dyn11
Yyn0

540

1990

 2.4

 520

 1600*1300*2200

315

970

4080

 1.8

 1085

 1800*1350*2200

500

1350

5790

 1.8

 1520

 2000*1400*2200

630

1530

 6840

 1.6

 1820

 2000*1400*2200

1000

2070

 9780

 1.4

 2550

 2450*1450*2200

1250

2380

11500 

 1.4

 2900

 2300*1500*2200

1600

2790

13800

 1.4

 3490

 2400*1550*2200

2000

3240

16300

 1.2

 4220

 2600*1600*2200

2500

3870

 19300

 1.2

 4955

 2600*1600*2200