logo
अच्छी कीमत  ऑनलाइन

उत्पादों का विवरण

घर > उत्पादों >
थ्री फेज पैड माउंटेड ट्रांसफार्मर
>
2550kVA Three Phase Pad Mounted Transformer Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed
विस्तृत जानकारी
उत्पत्ति के प्लेस:
चीन
प्रमाणन:
UL/cUL,CE,ISO
क्षमता:
2550kVA
प्रकार:
पैड माउंटेड, रेडियल फ़ीड
मॉडल नंबर:
12870V
टैपिंग रेंज:
14400V, 13800V, 13200V, 12870V, 12470V, 12000V, 11500V
उत्पत्ति का स्थान:
480V
न्यूनतम आदेश मात्रा:
YNd1
भुगतान की शर्तें:
ओनान; स्वयं ठंडा
मानक:
ANSI C57.12.34
प्रसव के समय:
30 दिन
आपूर्ति की क्षमता:
1000सेट/माह
उत्पाद का वर्णन

2550kVA Three Phase Pad Mounted Transformer Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed

 

 

This 2550 kVA three-phase pad-mounted step-down transformer is designed for radial feed distribution networks, widely applied in commercial, industrial and outdoor utility power supply projects. Built in compliance with ANSI C57.12.34 standard, it adopts ONAN cooling, aluminum windings and NEMA 3R enclosure, with complete standard accessories and stable electrical performance. As a certified manufacturer, Winley Electric holds UL certification, guaranteeing full safety compliance and reliable operation for North American market applications.

 

2550kVA  Three Phase Pad Mounted Transformer  Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed 0

 

2550kVA  Three Phase Pad Mounted Transformer  Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed 1

 

2550kVA  Three Phase Pad Mounted Transformer  Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed 2

 

As a professional manufacturer with advanced production lines, Winley Electric boasts strong mass production capacity, enabling us to deliver high-quality transformers in large quantities while ensuring consistent product performance and on-time delivery. Our standardized production processes, strict quality control systems, and mature supply chain management allow us to meet the bulk order needs of global clients, reducing lead times and providing cost-effective solutions without compromising quality.

 

2550kVA  Three Phase Pad Mounted Transformer  Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed 3

 

Main data

 

The transformer supports both radial and loop feed arrangements, with HV terminals available in dead and live front types. The HV BIL ranges from 45 – 150 kV for dead front and 200 kV for live front, while the LV BIL is 30 – 60 kV, fully meeting the insulation and voltage resistance requirements of different application scenarios. The control cabinet is divided into a high-voltage room and a low-voltage room, separated by a rigid steel partition for clear functional division and enhanced safety. It is equipped with a three-point latching system for the low-voltage door, and the high-voltage door can only be opened after the low-voltage door is opened, effectively ensuring operational safety.

 

specification data
No. Particulars Unit Specification Remark
1 Type ~ pad mounted, radial feed step down
2 Rated capacity kVA 2550  
3 No. of Phase ~ 3 phases  
4 Primary voltage V 12870 Wye-N
5 Secondary voltage V 480 delta
Secondary buhsing ~ (3) BIL30kV 10-hole NEMA spade live front
6 Tapping type ~ off-circuit  
7 Tapping range V 14400, 13800, 13200, 12870, 12470, 12000, 11500
8 Cooling method ~ ONAN  
9 Rated frequency Hz 60  
10 Vector group ~ YNd1  
11 Insulation class ~ A  
12 Temperature rise 65  
13 Off-load loss W 2500 ±10% tolerance
14 On-load loss (85℃) W 24500
15 Impedance % 5.75~6.75
16 Winding material ~ Aluminum  
17 Core material ~ silicon steel  
18 Cooling material ~ Mineral oil  
19 Tank&enclosure ~ NEMA 3R (green)  
20 Dimension inch 75*93*75 for reference only
21 Weight lbs 12556
22 Service condition ~ indoor or outdoor  
23 Sea level M ≤1000  
24 Standard ~ ANSI C57.12.34  

 

Technical drawings


1)The transformer part and the control cabinet part of the United States variation, of which the transformer part is a fully sealed structure, and the insulating oil can be two types of high ignition point oil or ordinary oil.
2)The control cabinet is divided into a high-voltage room and a low-voltage room.
3)The high-voltage room is equipped with: high-voltage cable plug, lightning arrester, load switch operating handle, non-excitation tap switch handle, plug-in fuse, pressure release valve, thermometer, pressure gauge, oil Position gauges, oil filling plugs, oil drain valves, etc., load switches, off-excitation tap changers, plug-in fuses, etc. are all immersed in transformer oil together with the transformer core. The high-voltage cable and the transformer are connected by elbow cable connectors.
4)The low-voltage side can be installed with air circuit breakers, current transformers, as well as electric energy meters, ammeters and voltmeters, and output circuits and capacitance compensation devices can be configured according to user needs.

 

2550kVA  Three Phase Pad Mounted Transformer  Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed 4

 

Production process

 

2550kVA  Three Phase Pad Mounted Transformer  Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed 5

 

2550kVA  Three Phase Pad Mounted Transformer  Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed 6

 

2550kVA  Three Phase Pad Mounted Transformer  Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed 7

 

2550kVA  Three Phase Pad Mounted Transformer  Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed 8

 

 

Winley Electric’s three-phase pad-mounted transformer stands out for its reliable performance, standardized production, and customer-centric design. Backed by our strong mass production capabilities and strict quality assurance, we are committed to providing durable, efficient, and cost-effective power distribution solutions to support your projects.

 

Specification

 

Rated Power
(KVA)
High Voltage
(KV)
Low Voltage
(V)
No-load Loss
(W)
On-load Loss
(W)
Height
(mm)
Depth
(mm)
Width
(mm)
Weight
(kg)
Weight
(Lbs)
75KVA 34.5KV
4.160KV
12.47KV
13.2KV
13.8KV
24940GrdY/14400
1247Grdy/7200
4160GrdY/2400
or others
277V
347V
480V
600V
120/240V
208GrdY/120
415GrdY/240
480GrdY/277
600Y/347
180 1250 1430 910 1930 645 1422
150KVA 280 2200 1530 980 1510 989 2180
300KVA 480 3650 1680 1080 1660 1415 3119
500KVA 680 5100 1790 1160 1810 1905 4200
750KVA 980 7500 2030 1300 2030 2755 6074
1000KVA 1150 10300 1854 1549 1651 3235 7132
1500KVA 1640 14500 2150 1570 2210 5835 12864
2000KVA 2160 20645 2220 1600 2380 6430 14175
2500KVA 2680 23786 2330 1650 3070 8865 19544
3000KVA 3300 30300 2460 1850 3260 11300 24912
3735KVA 4125 37875 2680 2060 4080 14400 31746

 

Production process

 

2550kVA  Three Phase Pad Mounted Transformer  Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed 9

2550kVA  Three Phase Pad Mounted Transformer  Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed 10

2550kVA  Three Phase Pad Mounted Transformer  Radial Feed 12.87KV To 480V ANSI C57 Standards UL Listed 11

 

FAQ

 

1. Q: Can I have a sample order?

A: Yes, we welcome sample order to test and check quality.

2. Q: What is the lead time?

A: Mass production time 15-25 days.

3. Q: How long is the warranty?

A: 24 monthes from B/L. If there are any accessory problems,just provide the photos of damaged accessory,then we will provide free service. According to the number of products,we will provide easily damaged accessories for free. we also can provide technical support if you need.

4. Q: Is OEM/ODM available?

A: Yes,it is! We are manufacturer with our own R&D team, we can customize products according to customer's drawing or requirements.

Customized services:

a. Customized color and special function.

b. Customized box.

c. Print customer's logo.

d. Your other ideas about product, we can help you design and put them into production. The above customized services must be confirmed before production.

5. Q: How to control the products quality?

A: Our company owns the core technology ,all kinds of products hold CE certificate. We have professional engineers. Workers are strictly required to make products according to the drawings. Each process has technical instructors.The QC supervisors will regularly inspect the production. We will do products performance tests during production, and comprehensive quality tests when the products is completed.