logo
Good price  online

products details

Home > Products >
Substation Power Transformer
>
2550kVA Three Phase Loop Feed Pad Mounted Transformer 24.94kV to 400V FR3 Oil
Detail Information
Place of Origin:
CHINA
Certification:
UL/cUL
Transformer Type:
Three Phase Pad Mounted Transformer
Rated Capacity:
2550kVA
Primary Voltage:
24.94kV
Secondary Voltage:
400V
Vector Group:
YNyn0
Frequency:
60Hz
Cooling Class:
KNAN
Winding Material:
Aluminum
Delivery Time:
4-6 weeks
Supply Ability:
300 set/month
Product Description

500kVA Skid-Mounted Step-Up Substation Transformer 415V to 1kV AS60076

Product Overview

The Winley ZGS-H-2550/24.94/0.4 is a 2550kVA three-phase oil-immersed pad-mounted transformer built to ANSI C57.12.34. Designed for 60Hz systems, it steps down 24940GrdY/14400V primary power to 400Y/231V for industrial plants and commercial grids standardized on 400V three-phase distribution.

  • 24.94kV to 400Y/231V Step-Down: Delivers 400Y/231V (3680.7A) via four 30kV BIL 12-hole NEMA spades to supply 400V 60Hz loads directly.

  • FR3 Natural Ester Oil (KNAN): Filled with non-PCB FR3 biodegradable ester fluid in a NEMA 3R enclosure for indoor and outdoor sites requiring higher fire safety.

  • Loop-Feed & Dual Fusing: Features six 25kV 200A dead-front bushing wells/inserts, three 2-position loadbreak switches, bayonet fuses, and current-limiting fuses for ring-main switching and overcurrent protection.

Product Display

Photos of Winley’s 2550kVA three-phase pad-mounted transformer (24.94kV to 400V), showing the enclosure and the high- and low-voltage compartments.

2550kVA Three Phase Loop Feed Pad Mounted Transformer 24.94kV to 400V FR3 Oil2550kVA Three Phase Loop Feed Pad Mounted Transformer 24.94kV to 400V FR3 Oil

2550kVA Three Phase Loop Feed Pad Mounted Transformer 24.94kV to 400V FR3 Oil    

Main data
Electrical ratings, construction details, and factory test results for model ZGS-H-2550/24.94/0.4.
Electrical Ratings
Specification Data Specification Data
Model ZGS-H-2550/24.94/0.4 Rated Capacity 2550kVA
Primary Voltage 24940GrdY/14400V Secondary Voltage 400Y/231V
Phase Three-phase Frequency 60Hz
Vector Group YNyn0 Primary and Secondary BIL 125kV / 30kV
Temperature Rise 65°C Standard ANSI/IEEE C57.12.34
Cooling, Fluid & Outdoor Construction
Specification Data Specification Data
Mounting Pad-mounted Feed Type Loop feed
Insulating Fluid FR3 natural ester Cooling Class KNAN
Winding Material Aluminum HV and LV Specified Enclosure NEMA 3R, Munsell Bell Green
Overall Dimensions 2800 × 2300 × 2100mm Weight 5600kg
Factory-Tested Performance
Specification Data Specification Data
No-Load Loss 2,182W Load Loss at 85°C 26,649W
Short-Circuit Impedance at 85°C 6.58% No-Load Current 0.15%
Drawing

General assembly drawing with outline dimensions and terminal layout for model ZGS-H-2550/24.94/0.4.

2550kVA Three Phase Loop Feed Pad Mounted Transformer 24.94kV to 400V FR3 Oil

Standard Features

Standard factory-configured components and mechanical accessories included with the 2550kVA Three Phase Pad Mounted Transformer.

  • High-Voltage Dead-Front Interface: Six 25kV, 200A bushing wells and inserts (H1A/H1B, H2A/H2B, H3A/H3B) with parking stands and drip shield for elbow connector termination.

  • Loadbreak Switching & Dual Fusing: Three 2-position loadbreak switches, three PRNT-80A bayonet fuses, and three XRNT-160A current-limiting fuses.

  • Off-Circuit Tap Changer: 5-position rotary tap changer (±2×2.5%) for de-energized primary voltage regulation.

  • Low-Voltage 12-Hole NEMA Spades: Four 30kV BIL secondary bushings (X0, X1, X2, X3) with 12-hole NEMA spades, mechanical supports, and common H0/X0 grounding.

  • Monitoring & Protection Gauges: Liquid level gauge, oil temperature gauge, vacuum pressure gauge, automatic pressure relief valve, and Schrader gas sampler valve.

  • Tank & Grounding Hardware: NEMA 3R Munsell Bell Green coated steel enclosure, 1" drain valve with 3/8" sampler, stainless steel ground pads, grounding lugs, lifting lugs, and jacking pads.

2550kVA Three Phase Loop Feed Pad Mounted Transformer 24.94kV to 400V FR3 Oil

Specification Selection Guide
Specification Available Options Specification Available Options
Capacity Range 45–5000kVA Maximum Capacity Up to 10MVA on request
Typical Ratings 75, 150, 225, 300, 500, 750, 1000, 1500, 2000, 2500, 3000kVA Frequency 50Hz / 60Hz
Primary Voltage 12.47kV, 13.2kV, 13.8kV, 24.94kV, 34.5kV, or custom Secondary Voltage 208Y/120V, 480Y/277V, 600Y/347V, 240V, 480V, 600V, or custom
Primary BIL 60–200kV Feed Type Loop Feed / Radial Feed
Winding Connection Delta–Wye, Grounded Wye–Wye, Delta–Delta, Wye–Wye, or custom Cooling Method ONAN / ONAF / KNAN
HV Terminations 200A Loadbreak, 600A Deadbreak, or Live-Front Porcelain Bushings Tap Changer DETC
Winding Material Copper / Aluminum Insulating Fluid Mineral Oil / Natural Ester


Applicable Standards: ANSI/IEEE C57 Series, CSA, DOE, and NEMA, as applicable
Certification: UL/cUL File E536138

Applications

This 2550kVA three-phase pad-mounted transformer supplies 400Y/231V, 60Hz power from 24.94kV underground loop feeders at industrial plants, commercial complexes, and campuses.

  • 60Hz Industrial Plants & Manufacturing Facilities Using 400V Equipment
    Suitable for industrial facilities served by 24.94kV feeders where production machinery, motor drives, and process lines require 400V, 60Hz power.
  • Commercial Complexes, Campuses & Ring-Main Distribution Networks
    The loop-feed configuration connects to 24.94kV underground distribution loops. Three two-position loadbreak switches support feeder sectionalizing.
  • Outdoor Sites Requiring High-Fire-Point Insulating Fluid
    The NEMA 3R enclosure supports outdoor pad installation. FR3 natural ester is suitable for projects that specify a high-fire-point, readily biodegradable insulating fluid.

2550kVA Three Phase Loop Feed Pad Mounted Transformer 24.94kV to 400V FR3 Oil

More Products:

Three-Phase Oil-Immersed Substation Transformers

600kVA Three Phase Pad Mounted Transformer 24940V to 480Y/277V Dead Front Step Down Transformer DOE 2016 Efficiency     1000kVA Three Phase Pad Mounted Distribution Transformer 24940Y/14400V to 480Y/277V UL Listed     2000kVA Three-Phase Loop-Feed Pad-Mounted Transformer 34500V to 480Y/277V For Data Center

FAQ
Q1: What is the lead time?

A: Winley delivers standard three-phase pad-mounted transformers with a 4–6 weeks production time after technical approval. We provide a detailed production schedule and real-time manufacturing photos to help track progress.

Q2: How soon can I get a quotation, and what is the MOQ?

A: We offer a flexible MOQ of just 1 unit.

Complete inquiries are quoted within 1–2 days with 24/7 support. Leveraging our extensive North American project experience, we ensure highly cost-effective and reliable solutions.

Q3: Is OEM/ODM available?

A: Yes, We accept OEM and ODM. Winley three-phase pad-mounted transformers are available in standard ratings from 45–5000kVA (and maximum capability up to 10 MVA), with HV systems up to 34.5 kV. We can customize electrical parameters, structure, fluid, protection, switches, gauges, tank and paint according to customer drawings, with the capability to integrate components from brands like Qualitrol, Eaton Cooper, and MR.

Q4: Do you provide UL/cUL and ANSI/IEEE support?

A: Yes. Our full range of products are UL/cUL-certified under UL File No. E536138, designed strictly in compliance with ANSI/IEEE, CSA, DOE, and NEMA requirements to meet grid connection and regulatory standards.

Q5: What documents can you provide for project approval?

A: We deliver a complete compliance package: approval drawings, datasheets, routine test reports, UL/cUL certs, DOE 2016 docs, and operation manuals. We also back your project with lifetime documentation support.

Q6: How do you ensure product quality?

A: Winley ensures quality through 4 annual unannounced UL audits and strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).

Q7: How long is the warranty?

A: 24 months from the B/L date, extendable up to 5 years upon request. During the warranty period, we provide free replacement parts upon receiving photos of any damaged accessories, include free spare parts based on order volume, and offer ongoing technical support.