40MVA Utility Substation Conservator Transformer 44kV to 34.5kV Oil Immersed ONAN CSA Standards
| Brand Name: | WINLEY |
| Model Number: | S-40000/44 |
| MOQ: | 1unit |
| Price: | $1000-$100000 |
| Packaging Details: | Plywood case |
| Payment Terms: | T/T |
Designed for utility substations and large industrial power systems, this 40 MVA conservator-type power transformer provides 44000V to 34500Y/19920V step-down service for high-capacity grounded-wye distribution. It is built with copper windings, mineral-oil insulation, a Dyn1 connection and ONAN cooling, and complies with IEEE/ANSI C57.12.00 and C57.12.34.
The single-unit 40 MVA capacity, which allows a 44kV source to supply a substantial 34.5kV distribution bus from one transformer position. Compared with dividing the same duty among multiple smaller units, this arrangement can reduce equipment footprint, primary and secondary interconnections, foundation requirements and system coordination work.
-
Single-Unit 40MVA Capacity
The full 40MVA rating allows a single transformer position to supply a substantial 34.5kV distribution bus from a 44kV source. This can reduce the footprint, foundations, cable connections and coordination requirements associated with installing multiple smaller transformers.
- Conservator-Type Oil Expansion System
The conservator system accommodates insulating-oil expansion and contraction as transformer load and outdoor temperature change. Combined with the dehydrating breather and gas relay, it supports controlled oil-level management and continuous outdoor operation.
| Specification | Data | Specification | Data |
|---|---|---|---|
| Product type | Three-phase conservator substation power transformer | Rated capacity | 40MVA / 40,000kVA |
| Model | S-40000/44 | Phase | Three phase |
| Operation | Step-down | Frequency | 60Hz |
| Primary voltage | 44000V | Secondary voltage | 34500Y/19920V |
| Cooling method | ONAN | Vector group | Dyn1 |
| HV/LV/Neutral BIL | 250/200/125kV | Insulation class | Class A |
| Impedance | 6.24% | Temperature rise | 55/65°C |
| Specification | Data | Specification | Data |
|---|---|---|---|
| Enclosure | NEMA 3R | Insulatin Winding | Copper |
| Overall Dimensions | 242.7 L × 169 W × 189 H in | Total Weight | 118,957 lb |
| Test Item | Tested Value | Test Item | Tested Value |
|---|---|---|---|
| No-Load Loss | 22.79kW | No-Load Current | 0.12% |
| Load Loss at 85°C | 142.085kW | Short-Circuit Impedance | 6.25% |
- Three top-mounted HV bushings — Provide the live-front connection points for the 44kV primary circuit.
- Three LV bushings and one X0 neutral bushing — Connect the 34500Y/19920V phases and grounded neutral to the downstream distribution system.
- Station-class surge arresters — Limit incoming overvoltage surges before they reach the transformer winding insulation.
- Conservator tank — Accommodates insulating-oil expansion and contraction during load and ambient-temperature changes.
- Gas relay — Detects gas accumulation or rapid oil movement associated with internal transformer conditions.
- Rapid pressure rise relay — Provides an indication when internal tank pressure increases abnormally fast.
- Automatic pressure relief device — Releases excessive internal pressure to protect the transformer tank.
- Magnetic oil level indicator — Provides a visible indication of the insulating-oil level.
- Oil temperature controller — Monitors top-oil temperature and supplies control or alarm contacts.
- Radiator fill and drain plugs — Support filling, draining and maintenance of the cooling sections.
- Drain valve with sampling connection — Allows insulating oil to be drained or sampled during maintenance and condition assessment.
- Tank and active-part lifting lugs — Provide designated lifting points for handling the tank and internal active assembly.
- Grounding terminals and tank grounding pads — Provide secure connection points for bonding the transformer tank to the station grounding system.
- Sector: Electric utilities and regional distribution networks
Suitable applications:
Substations stepping down 44kV subtransmission power to a grounded 34.5kV distribution bus.
Why this transformer fits:
The 40MVA rating, Dyn1 connection and 34500Y/19920V output directly match high-capacity 34.5kV distribution duty.
- Sector: Mining, metals, chemical processing and large manufacturing facilities
Suitable applications:
Facilities receiving power at 44kV and operating an internal 34.5kV medium-voltage distribution network.
Why this transformer fits:
The single-unit 40MVA capacity supports concentrated process loads, while the grounded-wye secondary provides a defined neutral for the downstream system.
- Sector: Transportation infrastructure, processing campuses and energy facilities
Suitable applications:
Projects requiring centralized high-capacity 34.5kV distribution from a 44kV utility or subtransmission source.
Why this transformer fits:
Outdoor conservator construction, ONAN cooling and a -40°C to +40°C ambient range support exposed substation service across demanding operating environments.
- Sector: Utility and industrial retrofit projects
Suitable applications:
Expansion or replacement of existing 44kV to 34.5kV transformer positions.
Why this transformer fits:
Five primary voltage positions, separated live-front HV/LV interfaces and defined foundation dimensions provide practical electrical and physical data for replacement planning.
| Rated Power (KVA) |
High Voltage (KV) |
Low Voltage (V) |
No-load Loss (W) |
On-load Loss (W) |
Height (mm) |
Depth (mm) |
Width (mm) |
Weight (kg) |
Weight (Lbs) |
|---|---|---|---|---|---|---|---|---|---|
| 75KVA | 34.5KV 4.160KV 12.47KV 13.2KV 13.8KV 24940GrdY/14400 1247Grdy/7200 4160GrdY/2400 or others |
277V 347V 480V 600V 120/240V 208GrdY/120 415GrdY/240 480GrdY/277 600Y/347 |
180 | 1250 | 1430 | 910 | 1930 | 645 | 1422 |
| 150KVA | 280 | 2200 | 1530 | 980 | 1510 | 989 | 2180 | ||
| 300KVA | 480 | 3650 | 1680 | 1080 | 1660 | 1415 | 3119 | ||
| 500KVA | 680 | 5100 | 1790 | 1160 | 1810 | 1905 | 4200 | ||
| 750KVA | 980 | 7500 | 2030 | 1300 | 2030 | 2755 | 6074 | ||
| 1000KVA | 1150 | 10300 | 1854 | 1549 | 1651 | 3235 | 7132 | ||
| 1500KVA | 1640 | 14500 | 2150 | 1570 | 2210 | 5835 | 12864 | ||
| 2000KVA | 2160 | 20645 | 2220 | 1600 | 2380 | 6430 | 14175 | ||
| 2500KVA | 2680 | 23786 | 2330 | 1650 | 3070 | 8865 | 19544 | ||
| 3000KVA | 3300 | 30300 | 2460 | 1850 | 3260 | 11300 | 24912 | ||
| 3735KVA | 4125 | 37875 | 2680 | 2060 | 4080 | 14400 | 31746 |
- With extensive experience in North American projects, Winley Electric designs substation transformers to meet applicable ANSI/IEEE, CSA, NEMA and related standard requirements.
- With a stable supply chain, mature production processes, Winley Electric can deliver substation power transformers within 12 weeks after technical confirmation.
- Winley Electric provides complete English technical documentation, 24/7 technical response, spare parts support, and a 2-year warranty to support project installation and long-term operation.
A: Winley provides clear capacity-based lead times after technical approval: 8-10 weeks for transformers below 10 MVA, 10-12 weeks for 10-40 MVA transformers, and 18-20 weeks for 40-100 MVA transformers. We also provide a detailed production schedule and real-time manufacturing photos to help track progress.We provide a detailed production schedule and real-time manufacturing photos to help track progress.
A: We offer a flexible MOQ of just 1 unit. Complete inquiries are quoted within 1-3 days with 24/7 support. Leveraging our extensive North American experience in renewable energy, data centers and large industrial projects, we ensure highly cost-effective and reliable solutions.
A: Yes, We accept OEM and ODM. Winley provides services for substation power transformers up to 100MVA, with HV systems up to 145kV. We can customize electrical parameters, structure, fluid, protection, switches, gauges, tank and paint according to customer drawings, with the capability to integrate components from brands like Qualitrol, Eaton Cooper, and MR.
A: Yes. Winley substation transformers are engineered and manufactured in strict accordance with ANSI/IEEE, CSA, NEMA, relevant ASTM standards and IEC 60076.We bring a proven track record across the United States and Canada, supporting critical applications in industrial manufacturing, renewable energy, and power distribution across a range of capacity and voltage requirements.
A: We deliver a complete compliance package: approval drawings, datasheets, nameplate drawings, routine test reports, installation manuals and accessory manuals. We also back your project with lifetime documentation support.
A: Winley ensures quality through strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).
Q7: Do you provide logistics and transportation support for large-scale projects?
A: Yes. Winley Electric provides tailored, fully controllable transportation solutions for large-scale transformer projects to ensure compliant customs clearance and zero-damage delivery. We actively assist in verifying critical logistics factors, including shipping dimensions, total weight, offloading conditions, site accessibility, and lifting/rigging requirements.
A: 24 months from B/L. During the warranty period, If there are any accessory problems, just provide photos of damaged accessory, then we will provide free service. According to the number of products, we will provide easily damaged accessories for free. We can also provide technical support if you need.