Substation Power Transformer
>
40MVA Utility Substation Conservator Transformer 44kV to 34.5kV Oil Immersed ONAN CSA Standards
Detail Information
Place of Origin:
CHINA
Certification:
ISO CE
Operation:
Step-down
Vector Group:
Dyn1
Secondary Voltage:
34500Y/19920V
Primary Voltage:
44000V
Cooling Class:
ONAN
Capacity:
40MVA
Type:
Substation Power Transformer
Standard:
ANSI IEEE
Insulation Class:
Class A
Frequency:
60Hz
Delivery Time:
90 days
Supply Ability:
100set/month
Product Description
40MVA Utility Substation Conservator Transformer 44kV to 34.5kV Oil Immersed ONAN CSA Standards
Product Overview

Designed for utility substations and large industrial power systems, this 40 MVA conservator-type power transformer provides 44000V to 34500Y/19920V step-down service for high-capacity grounded-wye distribution. It is built with copper windings, mineral-oil insulation, a Dyn1 connection and ONAN cooling, and complies with IEEE/ANSI C57.12.00 and C57.12.34.

The single-unit 40 MVA capacity, which allows a 44kV source to supply a substantial 34.5kV distribution bus from one transformer position. Compared with dividing the same duty among multiple smaller units, this arrangement can reduce equipment footprint, primary and secondary interconnections, foundation requirements and system coordination work.

Product HighLights
  • Single-Unit 40MVA Capacity

    The full 40MVA rating allows a single transformer position to supply a substantial 34.5kV distribution bus from a 44kV source. This can reduce the footprint, foundations, cable connections and coordination requirements associated with installing multiple smaller transformers.

  • Conservator-Type Oil Expansion System

The conservator system accommodates insulating-oil expansion and contraction as transformer load and outdoor temperature change. Combined with the dehydrating breather and gas relay, it supports controlled oil-level management and continuous outdoor operation.

Product Display
40MVA Utility Substation Conservator Transformer 44kV to 34.5kV Oil Immersed ONAN CSA Standards
40MVA Utility Substation Conservator Transformer 44kV to 34.5kV Oil Immersed ONAN CSA Standards
40MVA Utility Substation Conservator Transformer 44kV to 34.5kV Oil Immersed ONAN CSA Standards
40MVA Utility Substation Conservator Transformer 44kV to 34.5kV Oil Immersed ONAN CSA Standards
40MVA Utility Substation Conservator Transformer 44kV to 34.5kV Oil Immersed ONAN CSA Standards    40MVA Utility Substation Conservator Transformer 44kV to 34.5kV Oil Immersed ONAN CSA Standards
Main Data
Electrical Ratings
Specification Data Specification Data
Product type Three-phase conservator substation power transformer Rated capacity 40MVA / 40,000kVA
Model S-40000/44 Phase Three phase
Operation Step-down Frequency 60Hz
Primary voltage 44000V Secondary voltage 34500Y/19920V
Cooling method ONAN Vector group Dyn1
HV/LV/Neutral BIL 250/200/125kV Insulation class Class A
Impedance 6.24% Temperature rise 55/65°C
Construction and Installation
Specification Data Specification Data
Enclosure NEMA 3R Insulatin Winding Copper
Overall Dimensions 242.7 L × 169 W × 189 H in Total Weight 118,957 lb
Factory-Tested Performance
Test Item Tested Value Test Item Tested Value
No-Load Loss 22.79kW No-Load Current 0.12%
Load Loss at 85°C 142.085kW Short-Circuit Impedance 6.25%
Technical drawings
40MVA Utility Substation Conservator Transformer 44kV to 34.5kV Oil Immersed ONAN CSA Standards
Standard Features
  • Three top-mounted HV bushings — Provide the live-front connection points for the 44kV primary circuit.
  • Three LV bushings and one X0 neutral bushing — Connect the 34500Y/19920V phases and grounded neutral to the downstream distribution system.
  • Station-class surge arresters — Limit incoming overvoltage surges before they reach the transformer winding insulation.
  • Conservator tank — Accommodates insulating-oil expansion and contraction during load and ambient-temperature changes.
  • Gas relay — Detects gas accumulation or rapid oil movement associated with internal transformer conditions.
  • Rapid pressure rise relay — Provides an indication when internal tank pressure increases abnormally fast.
  • Automatic pressure relief device — Releases excessive internal pressure to protect the transformer tank.
  • Magnetic oil level indicator — Provides a visible indication of the insulating-oil level.
  • Oil temperature controller — Monitors top-oil temperature and supplies control or alarm contacts.
  • Radiator fill and drain plugs — Support filling, draining and maintenance of the cooling sections.
  • Drain valve with sampling connection — Allows insulating oil to be drained or sampled during maintenance and condition assessment.
  • Tank and active-part lifting lugs — Provide designated lifting points for handling the tank and internal active assembly.
  • Grounding terminals and tank grounding pads — Provide secure connection points for bonding the transformer tank to the station grounding system.
Applications
  • Sector: Electric utilities and regional distribution networks

Suitable applications:
Substations stepping down 44kV subtransmission power to a grounded 34.5kV distribution bus.

Why this transformer fits:
The 40MVA rating, Dyn1 connection and 34500Y/19920V output directly match high-capacity 34.5kV distribution duty.

  • Sector: Mining, metals, chemical processing and large manufacturing facilities

Suitable applications:
Facilities receiving power at 44kV and operating an internal 34.5kV medium-voltage distribution network.

Why this transformer fits:
The single-unit 40MVA capacity supports concentrated process loads, while the grounded-wye secondary provides a defined neutral for the downstream system.

  • Sector: Transportation infrastructure, processing campuses and energy facilities

Suitable applications:
Projects requiring centralized high-capacity 34.5kV distribution from a 44kV utility or subtransmission source.

Why this transformer fits:
Outdoor conservator construction, ONAN cooling and a -40°C to +40°C ambient range support exposed substation service across demanding operating environments.

  • Sector: Utility and industrial retrofit projects

Suitable applications:
Expansion or replacement of existing 44kV to 34.5kV transformer positions.

Why this transformer fits:
Five primary voltage positions, separated live-front HV/LV interfaces and defined foundation dimensions provide practical electrical and physical data for replacement planning.

Specification
Rated Power
(KVA)
High Voltage
(KV)
Low Voltage
(V)
No-load Loss
(W)
On-load Loss
(W)
Height
(mm)
Depth
(mm)
Width
(mm)
Weight
(kg)
Weight
(Lbs)
75KVA 34.5KV
4.160KV
12.47KV
13.2KV
13.8KV
24940GrdY/14400
1247Grdy/7200
4160GrdY/2400
or others
277V
347V
480V
600V
120/240V
208GrdY/120
415GrdY/240
480GrdY/277
600Y/347
180 1250 1430 910 1930 645 1422
150KVA 280 2200 1530 980 1510 989 2180
300KVA 480 3650 1680 1080 1660 1415 3119
500KVA 680 5100 1790 1160 1810 1905 4200
750KVA 980 7500 2030 1300 2030 2755 6074
1000KVA 1150 10300 1854 1549 1651 3235 7132
1500KVA 1640 14500 2150 1570 2210 5835 12864
2000KVA 2160 20645 2220 1600 2380 6430 14175
2500KVA 2680 23786 2330 1650 3070 8865 19544
3000KVA 3300 30300 2460 1850 3260 11300 24912
3735KVA 4125 37875 2680 2060 4080 14400 31746
Production process
40MVA Utility Substation Conservator Transformer 44kV to 34.5kV Oil Immersed ONAN CSA Standards
Why Choose US
  1. With extensive experience in North American projects, Winley Electric designs substation transformers to meet applicable ANSI/IEEE, CSA, NEMA and related standard requirements.
  2. With a stable supply chain, mature production processes, Winley Electric can deliver substation power transformers within 12 weeks after technical confirmation.
  3. Winley Electric provides complete English technical documentation, 24/7 technical response, spare parts support, and a 2-year warranty to support project installation and long-term operation.
40MVA Utility Substation Conservator Transformer 44kV to 34.5kV Oil Immersed ONAN CSA Standards
FAQ:
Q1: What is the lead time?

A: Winley provides clear capacity-based lead times after technical approval: 8-10 weeks for transformers below 10 MVA, 10-12 weeks for 10-40 MVA transformers, and 18-20 weeks for 40-100 MVA transformers. We also provide a detailed production schedule and real-time manufacturing photos to help track progress.We provide a detailed production schedule and real-time manufacturing photos to help track progress.

Q2: How soon can I get a quotation, and what is the MOQ?

A: We offer a flexible MOQ of just 1 unit. Complete inquiries are quoted within 1-3 days with 24/7 support. Leveraging our extensive North American experience in renewable energy, data centers and large industrial projects, we ensure highly cost-effective and reliable solutions.

Q3: Is OEM/ODM available?

A: Yes, We accept OEM and ODM. Winley provides services for substation power  transformers up to 100MVA, with HV systems up to 145kV. We can customize electrical parameters, structure, fluid, protection, switches, gauges, tank and paint according to customer drawings, with the capability to integrate components from brands like Qualitrol, Eaton Cooper, and MR.

Q4: Do your substation transformers meet North American standards, and do you have North American project experience?

A: Yes. Winley substation transformers are engineered and manufactured in strict accordance with ANSI/IEEE, CSA, NEMA, relevant ASTM standards and IEC 60076.We bring a proven track record across the United States and Canada, supporting critical applications in industrial manufacturing, renewable energy, and power distribution across a range of capacity and voltage requirements.

Q5: What documents can you provide for project approval?

A: We deliver a complete compliance package: approval drawings, datasheets, nameplate drawings, routine test reports, installation manuals and accessory manuals. We also back your project with lifetime documentation support.

Q6: How do you ensure product quality?

A: Winley ensures quality through strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).

Q7: Do you provide logistics and transportation support for large-scale projects? 

A: Yes. Winley Electric provides tailored, fully controllable transportation solutions for large-scale transformer projects to ensure compliant customs clearance and zero-damage delivery. We actively assist in verifying critical logistics factors, including shipping dimensions, total weight, offloading conditions, site accessibility, and lifting/rigging requirements.

Q8: How long is the warranty?

A: 24 months from B/L. During the warranty period, If there are any accessory problems, just provide photos of damaged accessory, then we will provide free service. According to the number of products, we will provide easily damaged accessories for free. We can also provide technical support if you need.