10 KVA Pole Mounted Transformer 24940Y To 120V Overhead Distribution Transformer Meets DOE 2016 CSA IEEE Standards
| Brand Name: | WINLEY |
| Model Number: | D-10/24.94 |
| MOQ: | 1unit |
| Price: | $1000-$10000 |
| Packaging Details: | Plywood case |
| Payment Terms: | T/T |
10 kVA Pole Mounted Transformer
,24940Y to 120V Overhead Distribution Transformer
,UL/cUL Listed Oil-Immersed Transformer
10 KVA Pole Mounted Transformer 24940Y To 120V Overhead Distribution Transformer Meets DOE 2016 CSA IEEE Standards UL/cUL Listed
Winley electric's single-phase fully complies with or even exceeds international standards such as ANSI/IEEE, CSA, and DOE. Single-phase has ul/cul, CSA, IEEE and other certificates. It has been exported to North America, Central and South America and other markets in large quantities.
![]()
UL/cUL Certification Certificate of Winley Electric
Main data
| Transformer Type | Overhead Distribution Transformer, Conventional Type |
| Phase | Single Phase |
| Capacity | 10 KVA |
| Primary Voltage | 24940GrdY/14400 |
| Secondary Voltage | 120/240V (L-N-L) |
| Secondary Phasor | Dual Winding Single Phase |
| Frequency | 60 Hz |
| Temperature Rise | 65°C |
| Insulation Rating | Class E Insulation - 120°C, 248°F |
| Cooling Class | ONAN; Self-Cooled |
| Efficiency Standard(s) | Meets DOE 2016 Standards, Meets CSA Standards Meets ANSI/IEEE Standards |
| Winding Material | Copper |
| Ambient Temperature Rating | 40°C |
| Ambient Operating Temperature Range | -40°C to +40°C (-50°F to +104°F) |
| Sound Level | 48 dBA |
| Dimensions* | 18.5''-W x 21.65''-D x 35.83''-H |
Technical drawings
![]()
Structural Features
The following is the introduction of the main parts of the single-phase pole-mounted transformer. The main parts(accessories) on the single phase pole mounted transformer include high voltage bushing, low voltage bushing, oil fill valve, oil drain valve with the sampler, and pressure relief valve, Lighting arrester, Internal current limiting fusing, Circuit breaker.
1. High voltage bushing
The main material of high voltage bushing is porcelain and its main role is to connect high voltage winding and external high voltage lines, insulation protection, protection against external intrusion, heat conduction and heat dissipation, etc., to ensure the normal operation and safety of the transformer.
2. Low voltage bushing
There are two types of low voltage bushing as spade type and clip type.
3. Oil fill valve
The role of the oil filling valve on the single phase pole mounted transformer is to fill the insulation oil into the tank.
4. Oil drain valve with sampler
The oil drain valve and sampler on the single phase pole mounted transformer are used to discharge air and moisture, remove sediment and impurities, ensure the quality and performance of the oil inside the transformer, and ensure the safe and stable operation of the transformer. Meanwhile, we can collect oil samples for analysis and testing.
5. Pressure relief valve
The pressure relief valve on the single phase pole mounted transformer is mainly used to protect the safe operation of the transformer, maintain normal working conditions, and adjust the gas pressure inside the transformer to ensure its stability and reliability.
6. Lighting arrester
The lighting arrester keeps the transformer safe from power surges caused by lightning, switching, and other HV sources. It shunts high voltage surges by grounding to avoid the direct impact of the transformer itself.
7. Internal current limiting fusing
The fuse is used to limit the transformer winding from being damaged when there are overload currents.
8. Circuit breaker
One secondary circuit breaker is above the winding inside the tank and here are the operating handle, overload reset, and signal light. It has the function of thermal protection, low oil lever protection, and allowing a percentage of power to go through the breaker to restore service when it trips.
Specifications
| 10kva-500kva Single-phase oil immersed transformer | ||||||
| Rated Cap acity(kVA) | High | Low Voltage(v) | Connection Symbol | Standard | Short-circuit impedance(%) | Efficiency |
| Voltage(v) | (%) | |||||
| 10 | 4160 7200 12000 12470 13200 13800 19920 24940 34500 |
110 220 230 400 480 |
II0,II6 | IEEE/ANSI/ DOE/CSA | 1.0-4.5% | 98.7 |
| 15 | 98.82 | |||||
| 25 | 98.95 | |||||
| 37.5 | 99.05 | |||||
| 50 | 99.11 | |||||
| 75 | 99.19 | |||||
| 100 | 99.25 | |||||
| 167 | 99.33 | |||||
| 250 | 99.39 | |||||
| 333 | 99.43 | |||||
| 500 | 99.49 | |||||