Pole Mounted Transformer
>
10 KVA Pole Mounted Transformer 24940Y To 120V Overhead Distribution Transformer  Meets DOE 2016 CSA IEEE Standards
Detail Information
Place of Origin:
CHINA
Certification:
UL,cUL,CE,ISO
Type:
Oil-Immersed Transformer
Capacity:
10 KVA
Primary Voltage:
24940Y/14400
Secondary Voltage:
120/240V
Insulation Rating:
Class E Insulation - 120°C, 248°F
Dimensions*:
18.5''-W X 21.65''-D X 35.83''-H
Application:
Distribution System
Certification:
UL/cUL
Delivery Time:
30days
Supply Ability:
5000set/month
Highlight:

10 kVA Pole Mounted Transformer

,

24940Y to 120V Overhead Distribution Transformer

,

UL/cUL Listed Oil-Immersed Transformer

Product Description

10 KVA Pole Mounted Transformer 24940Y To 120V Overhead Distribution Transformer Meets DOE 2016 CSA IEEE Standards UL/cUL Listed

 

 

Winley electric's single-phase fully complies with or even exceeds international standards such as ANSI/IEEE, CSA, and DOE. Single-phase has ul/cul, CSA, IEEE and other certificates. It has been exported to North America, Central and South America and other markets in large quantities.

 

10 KVA Pole Mounted Transformer 24940Y To 120V Overhead Distribution Transformer  Meets DOE 2016 CSA IEEE Standards 0     10 KVA Pole Mounted Transformer 24940Y To 120V Overhead Distribution Transformer  Meets DOE 2016 CSA IEEE Standards 1

UL/cUL Certification Certificate of Winley Electric

 

 

Main data

 

Transformer Type Overhead Distribution Transformer, Conventional Type
Phase Single Phase
Capacity 10 KVA
Primary Voltage 24940GrdY/14400
Secondary Voltage 120/240V (L-N-L)
Secondary Phasor Dual Winding Single Phase
Frequency 60 Hz
Temperature Rise 65°C
Insulation Rating Class E Insulation - 120°C, 248°F
Cooling Class ONAN; Self-Cooled
Efficiency Standard(s) Meets DOE 2016 Standards, Meets CSA Standards Meets ANSI/IEEE Standards
Winding Material Copper
Ambient Temperature Rating 40°C
Ambient Operating Temperature Range -40°C to +40°C (-50°F to +104°F)
Sound Level 48 dBA
Dimensions* 18.5''-W x 21.65''-D x 35.83''-H

 

Technical drawings

 

10 KVA Pole Mounted Transformer 24940Y To 120V Overhead Distribution Transformer  Meets DOE 2016 CSA IEEE Standards 2

 

Structural Features

 

The following is the introduction of the main parts of the single-phase pole-mounted transformer. The main parts(accessories) on the single phase pole mounted transformer include high voltage bushing, low voltage bushing, oil fill valve, oil drain valve with the sampler, and pressure relief valve, Lighting arrester, Internal current limiting fusing, Circuit breaker.

 

1. High voltage bushing
The main material of high voltage bushing is porcelain and its main role is to connect high voltage winding and external high voltage lines, insulation protection, protection against external intrusion, heat conduction and heat dissipation, etc., to ensure the normal operation and safety of the transformer.
2. Low voltage bushing
There are two types of low voltage bushing as spade type and clip type.
3. Oil fill valve
The role of the oil filling valve on the single phase pole mounted transformer is to fill the insulation oil into the tank.
4. Oil drain valve with sampler
The oil drain valve and sampler on the single phase pole mounted transformer are used to discharge air and moisture, remove sediment and impurities, ensure the quality and performance of the oil inside the transformer, and ensure the safe and stable operation of the transformer. Meanwhile, we can collect oil samples for analysis and testing.
5. Pressure relief valve
The pressure relief valve on the single phase pole mounted transformer is mainly used to protect the safe operation of the transformer, maintain normal working conditions, and adjust the gas pressure inside the transformer to ensure its stability and reliability.
6. Lighting arrester
The lighting arrester keeps the transformer safe from power surges caused by lightning, switching, and other HV sources. It shunts high voltage surges by grounding to avoid the direct impact of the transformer itself.
7. Internal current limiting fusing
The fuse is used to limit the transformer winding from being damaged when there are overload currents.
8. Circuit breaker
One secondary circuit breaker is above the winding inside the tank and here are the operating handle, overload reset, and signal light. It has the function of thermal protection, low oil lever protection, and allowing a percentage of power to go through the breaker to restore service when it trips.

 

 

Specifications

 

10kva-500kva Single-phase oil immersed transformer
Rated Cap acity(kVA) High Low Voltage(v) Connection Symbol Standard Short-circuit impedance(%) Efficiency
Voltage(v) (%)
10 4160
7200
12000
12470
13200
13800
19920
24940
34500
110
220
230
400
480
II0,II6 IEEE/ANSI/ DOE/CSA 1.0-4.5% 98.7
15 98.82
25 98.95
37.5 99.05
50 99.11
75 99.19
100 99.25
167 99.33
250 99.39
333 99.43
500 99.49

 

Production process

 

10 KVA Pole Mounted Transformer 24940Y To 120V Overhead Distribution Transformer  Meets DOE 2016 CSA IEEE Standards 3

10 KVA Pole Mounted Transformer 24940Y To 120V Overhead Distribution Transformer  Meets DOE 2016 CSA IEEE Standards 4

10 KVA Pole Mounted Transformer 24940Y To 120V Overhead Distribution Transformer  Meets DOE 2016 CSA IEEE Standards 5