100kVA Single Phase Pole Mounted Transformer 34500Y/19920V to 120/240V Overhead Distribution Transformer ANSI/IEEE DOE 2016 Standards
| Nama merek: | WINLEY |
| Nomor Model: | D11-100/34.5/0.12-0.24 |
| MOQ: | 1 unit |
| Harga: | $1000-$100000 |
| Rincian kemasan: | kasus kayu lapis |
| Ketentuan Pembayaran: | T/T |
Best for:
Suitable for utility distribution points, rural overhead distribution, agricultural service and outdoor single phase power supply projects requiring 34500Y/19920V to 120/240V step-down service.
Customizable Specifications:
kVA, primary voltage, secondary voltage, frequency, vector group / phasor, feed type, standard, accessories, destination port.
For utility distribution points, rural overhead distribution and outdoor single phase service connections, this transformer is suitable for projects requiring medium-voltage step-down power supply. The unit is a 100kVA single phase liquid filled pole mounted transformer configured for 34500Y/19920V to 120/240V voltage conversion.
Its ONAN self-cooled design, mineral oil non-PCB insulating fluid, copper winding, 200/30kV BIL rating, 5-position tap changer and live bushing lug arrangement help match project requirements for voltage, insulation level, installation method and terminal interface. Buyers can use these specifications for quotation, technical approval and project specification confirmation.
Product Photos
![]()
![]()
Main Data
| Item | Data |
|---|---|
| Product type | Overhead distribution transformer |
| Phase | Single phase |
| Primary voltage | 34500GrdY/19920V |
| Secondary voltage | 120/240V |
| Frequency | 60Hz |
| HV BIL / LV BIL | 200kV / 30kV |
| Cooling method | ONAN |
| Winding material | Copper |
| Temperature rise | 65°C |
| No-load loss | 203W |
| Load loss | 819W at 85°C |
| Impedance | 2.26% at 85°C |
| Dimensions | 28.0" W × 35.2" D × 61.8" H |
| Total weight | 1962 lbs |
Technical drawings
![]()
Product Highlights
- 5-Position Tap Changer
The 5-position tap changer with 2.5% steps supports voltage adjustment during specification matching, site voltage review and commissioning preparation. - NEMA 4-Hole Terminal Interfaces
The porcelain high-voltage bushing with aluminum NEMA 4-hole terminal and low-voltage 4-hole spade terminals supports connector selection and field wiring review. - Protection and Grounding Provisions
Primary lightning arrester, secondary circuit breaker, pressure relief device, tank grounding lug and lifting lugs support protection, handling and maintenance planning.
| Sector | Suitable applications |
|---|---|
| Utility Distribution | Utility distribution points and overhead service drops |
| Rural Overhead Distribution | Rural homes, remote buildings and small community service points |
| Agricultural Power Supply | Farms, barns, irrigation controls and agricultural auxiliary loads |
| Commercial Power Supply | Small shops, roadside facilities and service buildings |
| Light Industrial Facilities | Small workshops, utility-owned auxiliary loads and outdoor equipment service |
| Outdoor Distribution Networks | Pole-line distribution, remote infrastructure and field service points |
| Rated Capacity (kVA) | High Voltage (kV) | No Load Loss (W) | On Load Loss (W) | Height (mm) | Depth (mm) | Width (mm) | Weight (kg) |
| 15kVA |
34.5/19.92 13.8/7.96 13.2/7.6 12.47/7.2 or others |
50 | 195 | 840 | 740 | 610 | 294 |
| 25kVA | 80 | 290 | 840 | 740 | 610 | 362 | |
| 37.5kVA | 106 | 360 | 840 | 760 | 610 | 476 | |
| 50kVA | 135 | 500 | 840 | 810 | 610 | 553 | |
| 75kVA | 190 | 650 | 840 | 860 | 610 | 672 | |
| 100kVA | 280 | 1010 | 910 | 1200 | 965 | 714 | |
| 167kVA | 435 | 1530 | 1000 | 1200 | 965 | 913 | |
| 250kVA | 550 | 2230 | 1250 | 1300 | 1430 | 1106 |
![]()
![]()