1500kVA Three Phase Pad Mounted Distribution Transformer 480V to 416Y/240V ANSI/IEEE Standards For Data Center
معلومات مفصلة
مكان المنشأ:
الصين
إصدار الشهادات:
UL/cUL
يكتب:
محول ثلاثي المراحل
عملية:
تنحى
سعة:
1500 كيلو فولت أمبير
الجهد الأساسي:
480 فولت
الجهد الثانوي:
416Y/240 فولت
مجموعة المتجهات:
DYN1
فئة التبريد:
كنان
معيار:
ANSI IEEE
وقت التسليم:
30 يوما
القدرة على العرض:
500 مجموعة / شهر
إبراز:

1500kVA pad mounted transformer 480V to 416Y/240V

,

Three phase distribution transformer ANSI/IEEE standards

,

Pad mounted transformer for data center

وصف المنتج
1500kVA Three Phase Pad Mounted Distribution Transformer 480V to 416Y/240V ANSI/IEEE Standards For Utility
Why Choose US
  1. Winley Electric three-phase transformers are UL/cUL Listed under File No. E536138, with ratings from 45 kVA through 10 MVA. They are designed and manufactured to meet applicable ANSI/IEEE, CSA, NEMA, and DOE 2016 requirements.
  2. With extensive experience in North American utility, industrial, and commercial projects, Winley Electric can deliver cost-effective customized solutions based on your specific project requirements.
  3. With a strong supply chain and experienced production team, Winley Electric support fast delivery with a 4–6 weeks production time after technical approval to help keep your project on schedule.
1500kVA Three Phase Pad Mounted Distribution Transformer 480V to 416Y/240V ANSI/IEEE Standards For Data Center 0
Product Overview

Engineered for reliable outdoor power distribution, this 1500kVA three-phase pad-mounted isolation transformer converts a standard 480V delta supply to 416Y/240V for downstream distribution. Compliant with ANSI C57.12.34 and UL/cUL Listed under File E536138, it provides a strong, code-aligned option for data centers, advanced manufacturing facilities and large commercial campuses integrating 400/415V-class imported or critical equipment into an existing 480V system.

The Dyn1 delta-wye configuration provides electrical isolation and creates a separately derived grounded-wye secondary with a dedicated neutral point for 240V line-to-neutral loads. Copper windings, FR3 non-PCB insulating fluid and KNAN natural cooling support dependable, low-maintenance outdoor operation. The enclosed, tamper-resistant pad-mounted structure helps protect internal connections, while 30kV BIL on both primary and secondary circuits provides robust insulation performance for demanding distribution environments.

Product Display
1500kVA Three Phase Pad Mounted Distribution Transformer 480V to 416Y/240V ANSI/IEEE Standards For Data Center 1
1500kVA Three Phase Pad Mounted Distribution Transformer 480V to 416Y/240V ANSI/IEEE Standards For Data Center 2
1500kVA Three Phase Pad Mounted Distribution Transformer 480V to 416Y/240V ANSI/IEEE Standards For Data Center 3      1500kVA Three Phase Pad Mounted Distribution Transformer 480V to 416Y/240V ANSI/IEEE Standards For Data Center 4
Main Data
Core Specifications
Specification Data Specification Data
Product Type Three-Phase Pad-Mounted Isolation Transformer Model ZGS11-1500/0.48/0.416
Rated Capacity 1500kVA Phase 3
Primary Voltage 480V Delta Secondary Voltage 416Y/240V
Rated Frequency 60Hz Vector Group Dyn1
Technical and Physical Data
Specification Data Specification Data
Cooling Method KNAN InsulatinWinding Copper
HV BIL / LV BIL 30kV / 30kV Temperature Rise 65°C
Overall Dimensions 94.2W × 83.8D × 69.9H in Total Weight 9,286 lb
Factory-Tested Performance
Test Item Tested Value Test Item Tested Value
No-Load Loss 1,442 W No-Load Current 0.13%
Load Loss at 85°C 19,331 W Short-Circuit Impedance 6.39%
Technical drawings
1500kVA Three Phase Pad Mounted Distribution Transformer 480V to 416Y/240V ANSI/IEEE Standards For Data Center 5
Standard Features
  • HV and LV Bushings — Three primary and four secondary bushings are fitted with 8-hole spade terminals and 30kV BIL for high-current cable connections.
  • Oil Level Gauge with Contacts — Provides local oil-level indication and electrical contacts for remote status signaling.
  • Vacuum Pressure Gauge — Displays the internal pressure or vacuum condition of the sealed transformer tank.
  • Pressure Relief Valve — Relieves abnormal internal tank pressure to help protect the transformer tank and seals.
  • Oil Temperature Gauge with Contacts — Monitors insulating-fluid temperature and provides contacts for alarm or control signals.
  • Gas Sampler Valve — Allows gas sampling for inspection and insulation-condition assessment.
  • Oil Fill Plug and Drain Valve — Supports oil filling, filtering, sampling and complete oil drainage during maintenance.
  • Grounding Pads and Lugs — Provides grounding points for the tank, neutral conductor and protective grounding system.
1500kVA Three Phase Pad Mounted Distribution Transformer 480V to 416Y/240V ANSI/IEEE Standards For Data Center 6
Applications
  • Sector: Industrial Manufacturing

Suitable applications:
Manufacturing plants adding 400/415V machinery, process equipment, production lines, or imported equipment packages to a 480V power system.

Why this transformer fits:
A single 1500kVA footprint simultaneously feeds 416V three-phase primary machinery and 240V line-to-neutral auxiliary controls or lighting, streamlining floor layouts.

  • Sector: Data Centers and Critical-Power Facilities

Suitable applications:
Facilities using specified 415/240V downstream distribution, UPS systems, PDUs, or other critical electrical equipment.

Why this transformer fits:
The isolated Dyn1 secondary topology safely provides a dedicated grounded neutral point, minimizing neutral-to-ground voltage issues and safeguarding sensitive electronic gear.

  • Sector: Commercial and Institutional Campuses

Suitable applications:
Large office campuses, hospitals, laboratories, and institutional facilities requiring localized 416Y/240V distribution.

Why this transformer fits:
The high-capacity 1500kVA output handles dense building loads seamlessly, while the compact outdoor pad-mounted profile relocates fluid-filled equipment entirely outside occupied spaces.

  • Sector: Infrastructure and Process Facilities

Suitable applications:
Water treatment plants, logistics centers, transportation facilities, and process sites with a 480V supply and 415V-class loads.

Why this transformer fits:
Heavy-duty weatherproofing, all-copper reliability, and integrated instrumentation make this unit well-suited for high-current site distribution under minimum maintenance regimes.

Specification
Rated Power
(KVA)
High Voltage
(KV)
Low Voltage
(V)
No-load Loss
(W)
On-load Loss
(W)
Height
(mm)
Depth
(mm)
Width
(mm)
Weight
(kg)
Weight
(Lbs)
75KVA 34.5KV
4.160KV
12.47KV
13.2KV
13.8KV
24940GrdY/14400
1247Grdy/7200
4160GrdY/2400
or others
277V
347V
480V
600V
120/240V
208GrdY/120
415GrdY/240
480GrdY/277
600Y/347
180 1250 1430 910 1930 645 1422
150KVA 280 2200 1530 980 1510 989 2180
300KVA 480 3650 1680 1080 1660 1415 3119
500KVA 680 5100 1790 1160 1810 1905 4200
750KVA 980 7500 2030 1300 2030 2755 6074
1000KVA 1150 10300 1854 1549 1651 3235 7132
1500KVA 1640 14500 2150 1570 2210 5835 12864
2000KVA 2160 20645 2220 1600 2380 6430 14175
2500KVA 2680 23786 2330 1650 3070 8865 19544
3000KVA 3300 30300 2460 1850 3260 11300 24912
3735KVA 4125 37875 2680 2060 4080 14400 31746
Production process
1500kVA Three Phase Pad Mounted Distribution Transformer 480V to 416Y/240V ANSI/IEEE Standards For Data Center 7
1500kVA Three Phase Pad Mounted Distribution Transformer 480V to 416Y/240V ANSI/IEEE Standards For Data Center 8
1500kVA Three Phase Pad Mounted Distribution Transformer 480V to 416Y/240V ANSI/IEEE Standards For Data Center 9
FAQ:
Q1: What is the standard lead time?

A: Winley delivers standard three-phase pad-mounted transformers with a 4–6 weeks production time after technical approval. We provide a detailed production schedule and real-time manufacturing photos to help track progress.

Q2: How soon can I get a quotation, and what is the MOQ?

A: We offer a flexible MOQ of just 1 unit. Complete inquiries are quoted within 1–2 days with 24/7 support. Leveraging our extensive North American project experience, we ensure highly cost-effective and reliable solutions.

Q3: Is OEM/ODM available?

A: Yes, We accept OEM and ODM. Winley three-phase pad-mounted transformers are available in standard ratings from 45–5000kVA (and maximum capability up to 10MVA), with HV systems up to 36 kV. We can customize electrical parameters, structure, fluid, protection, switches, gauges, tank and paint according to customer drawings, with the capability to integrate components from brands like Qualitrol, Eaton Cooper, and MR.

Q4: Do you provide UL/cUL and ANSI/IEEE support?

A: Yes. Our full range of products are UL/cUL-certified under UL File No. E536138, designed strictly in compliance with ANSI/IEEE, CSA, DOE, and NEMA requirements to meet grid connection and regulatory standards.

Q5: What documents can you provide for project approval?

A: We deliver a complete compliance package: approval drawings, datasheets, routine test reports, UL/cUL certs, DOE 2016 docs, and operation manuals. We also back your project with lifetime documentation support.

Q6: How do you ensure product quality?

A: Winley ensures quality through 4 annual unannounced UL audits and strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).

Q7: How long is the warranty?

A: 24 months from B/L. During the warranty period, If there are any accessory problems, just provide photos of damaged accessory, then we will provide free service. According to the number of products, we will provide easily damaged accessories for free. We can also provide technical support if you need.