1500kVA Three Phase Pad Mounted Distribution Transformer 480V to 416Y/240V ANSI/IEEE Standards For Data Center
| Наименование марки: | WINLEY |
| Номер модели: | ЗГС11-1500/0,48/0,416 |
| МОК: | 1 единица |
| Цена: | $1000-$100000 |
| Подробная информация об упаковке: | фанерный корпус |
| Условия оплаты: | Т/Т |
1500kVA pad mounted transformer 480V to 416Y/240V
,Three phase distribution transformer ANSI/IEEE standards
,Pad mounted transformer for data center
- Winley Electric three-phase transformers are UL/cUL Listed under File No. E536138, with ratings from 45 kVA through 10 MVA. They are designed and manufactured to meet applicable ANSI/IEEE, CSA, NEMA, and DOE 2016 requirements.
- With extensive experience in North American utility, industrial, and commercial projects, Winley Electric can deliver cost-effective customized solutions based on your specific project requirements.
- With a strong supply chain and experienced production team, Winley Electric support fast delivery with a 4–6 weeks production time after technical approval to help keep your project on schedule.
Engineered for reliable outdoor power distribution, this 1500kVA three-phase pad-mounted isolation transformer converts a standard 480V delta supply to 416Y/240V for downstream distribution. Compliant with ANSI C57.12.34 and UL/cUL Listed under File E536138, it provides a strong, code-aligned option for data centers, advanced manufacturing facilities and large commercial campuses integrating 400/415V-class imported or critical equipment into an existing 480V system.
The Dyn1 delta-wye configuration provides electrical isolation and creates a separately derived grounded-wye secondary with a dedicated neutral point for 240V line-to-neutral loads. Copper windings, FR3 non-PCB insulating fluid and KNAN natural cooling support dependable, low-maintenance outdoor operation. The enclosed, tamper-resistant pad-mounted structure helps protect internal connections, while 30kV BIL on both primary and secondary circuits provides robust insulation performance for demanding distribution environments.
| Specification | Data | Specification | Data |
|---|---|---|---|
| Product Type | Three-Phase Pad-Mounted Isolation Transformer | Model | ZGS11-1500/0.48/0.416 |
| Rated Capacity | 1500kVA | Phase | 3 |
| Primary Voltage | 480V Delta | Secondary Voltage | 416Y/240V |
| Rated Frequency | 60Hz | Vector Group | Dyn1 |
| Specification | Data | Specification | Data |
|---|---|---|---|
| Cooling Method | KNAN | InsulatinWinding | Copper |
| HV BIL / LV BIL | 30kV / 30kV | Temperature Rise | 65°C |
| Overall Dimensions | 94.2W × 83.8D × 69.9H in | Total Weight | 9,286 lb |
| Test Item | Tested Value | Test Item | Tested Value |
|---|---|---|---|
| No-Load Loss | 1,442 W | No-Load Current | 0.13% |
| Load Loss at 85°C | 19,331 W | Short-Circuit Impedance | 6.39% |
- HV and LV Bushings — Three primary and four secondary bushings are fitted with 8-hole spade terminals and 30kV BIL for high-current cable connections.
- Oil Level Gauge with Contacts — Provides local oil-level indication and electrical contacts for remote status signaling.
- Vacuum Pressure Gauge — Displays the internal pressure or vacuum condition of the sealed transformer tank.
- Pressure Relief Valve — Relieves abnormal internal tank pressure to help protect the transformer tank and seals.
- Oil Temperature Gauge with Contacts — Monitors insulating-fluid temperature and provides contacts for alarm or control signals.
- Gas Sampler Valve — Allows gas sampling for inspection and insulation-condition assessment.
- Oil Fill Plug and Drain Valve — Supports oil filling, filtering, sampling and complete oil drainage during maintenance.
- Grounding Pads and Lugs — Provides grounding points for the tank, neutral conductor and protective grounding system.
- Sector: Industrial Manufacturing
Suitable applications:
Manufacturing plants adding 400/415V machinery, process equipment, production lines, or imported equipment packages to a 480V power system.
Why this transformer fits:
A single 1500kVA footprint simultaneously feeds 416V three-phase primary machinery and 240V line-to-neutral auxiliary controls or lighting, streamlining floor layouts.
- Sector: Data Centers and Critical-Power Facilities
Suitable applications:
Facilities using specified 415/240V downstream distribution, UPS systems, PDUs, or other critical electrical equipment.
Why this transformer fits:
The isolated Dyn1 secondary topology safely provides a dedicated grounded neutral point, minimizing neutral-to-ground voltage issues and safeguarding sensitive electronic gear.
- Sector: Commercial and Institutional Campuses
Suitable applications:
Large office campuses, hospitals, laboratories, and institutional facilities requiring localized 416Y/240V distribution.
Why this transformer fits:
The high-capacity 1500kVA output handles dense building loads seamlessly, while the compact outdoor pad-mounted profile relocates fluid-filled equipment entirely outside occupied spaces.
- Sector: Infrastructure and Process Facilities
Suitable applications:
Water treatment plants, logistics centers, transportation facilities, and process sites with a 480V supply and 415V-class loads.
Why this transformer fits:
Heavy-duty weatherproofing, all-copper reliability, and integrated instrumentation make this unit well-suited for high-current site distribution under minimum maintenance regimes.
| Rated Power (KVA) |
High Voltage (KV) |
Low Voltage (V) |
No-load Loss (W) |
On-load Loss (W) |
Height (mm) |
Depth (mm) |
Width (mm) |
Weight (kg) |
Weight (Lbs) |
|---|---|---|---|---|---|---|---|---|---|
| 75KVA | 34.5KV 4.160KV 12.47KV 13.2KV 13.8KV 24940GrdY/14400 1247Grdy/7200 4160GrdY/2400 or others |
277V 347V 480V 600V 120/240V 208GrdY/120 415GrdY/240 480GrdY/277 600Y/347 |
180 | 1250 | 1430 | 910 | 1930 | 645 | 1422 |
| 150KVA | 280 | 2200 | 1530 | 980 | 1510 | 989 | 2180 | ||
| 300KVA | 480 | 3650 | 1680 | 1080 | 1660 | 1415 | 3119 | ||
| 500KVA | 680 | 5100 | 1790 | 1160 | 1810 | 1905 | 4200 | ||
| 750KVA | 980 | 7500 | 2030 | 1300 | 2030 | 2755 | 6074 | ||
| 1000KVA | 1150 | 10300 | 1854 | 1549 | 1651 | 3235 | 7132 | ||
| 1500KVA | 1640 | 14500 | 2150 | 1570 | 2210 | 5835 | 12864 | ||
| 2000KVA | 2160 | 20645 | 2220 | 1600 | 2380 | 6430 | 14175 | ||
| 2500KVA | 2680 | 23786 | 2330 | 1650 | 3070 | 8865 | 19544 | ||
| 3000KVA | 3300 | 30300 | 2460 | 1850 | 3260 | 11300 | 24912 | ||
| 3735KVA | 4125 | 37875 | 2680 | 2060 | 4080 | 14400 | 31746 |
A: Winley delivers standard three-phase pad-mounted transformers with a 4–6 weeks production time after technical approval. We provide a detailed production schedule and real-time manufacturing photos to help track progress.
A: We offer a flexible MOQ of just 1 unit. Complete inquiries are quoted within 1–2 days with 24/7 support. Leveraging our extensive North American project experience, we ensure highly cost-effective and reliable solutions.
A: Yes, We accept OEM and ODM. Winley three-phase pad-mounted transformers are available in standard ratings from 45–5000kVA (and maximum capability up to 10MVA), with HV systems up to 36 kV. We can customize electrical parameters, structure, fluid, protection, switches, gauges, tank and paint according to customer drawings, with the capability to integrate components from brands like Qualitrol, Eaton Cooper, and MR.
A: Yes. Our full range of products are UL/cUL-certified under UL File No. E536138, designed strictly in compliance with ANSI/IEEE, CSA, DOE, and NEMA requirements to meet grid connection and regulatory standards.
A: We deliver a complete compliance package: approval drawings, datasheets, routine test reports, UL/cUL certs, DOE 2016 docs, and operation manuals. We also back your project with lifetime documentation support.
A: Winley ensures quality through 4 annual unannounced UL audits and strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).
A: 24 months from B/L. During the warranty period, If there are any accessory problems, just provide photos of damaged accessory, then we will provide free service. According to the number of products, we will provide easily damaged accessories for free. We can also provide technical support if you need.