5000/6250/7000kVA Three Phase Pad Mounted Transformer 34.5kV Multi-Tap to 480V UL-Listed
| Brand Name: | WINLEY |
| Model Number: | ZGSL-Z-5000(6250-7000)/34.5/0.48 |
| MOQ: | 1unit |
| Price: | $1000-$100000 |
| Packaging Details: | Plywood case |
| Payment Terms: | T/T |
5000/6250/7000kVA Three Phase Pad Mounted Transformer 34.5kV Multi-Tap to 480V UL-Listed
The Winley ZGSL-Z-5000(6250-7000)/34.5/0.48 is a three-phase, liquid-immersed pad-mounted transformer built to ANSI C57.12.34, DOE 2016, and UL Listed standards. Designed for 60Hz indoor and outdoor distribution, it steps down medium-voltage primary power to a 480V Delta secondary for commercial, industrial, and utility loads.
-
5000/6250/7000kVA ONAN/ONAF Rating: Delivers 5000kVA (55°C) and 6250kVA (65°C) self-cooled, and up to 7000kVA (65°C) with two 480V forced-air cooling fans.
-
34.5kV–12.47kV 8-Step Tap Changer: Supports eight primary voltage positions from 34500V down to 12470V for grid voltage flexibility.
-
480V High-Current Output & Protection: Supplies 480V Delta via three 20-hole LV bushings with 150kV/30kV BIL and under-oil 36kV MOV arresters.
Photos of Winley's 5000/6250/7000kVA three-phase pad-mounted transformer (34.5kV multi-tap to 480V), showing the Munsell Bell Green enclosure, nameplate, and high- and low-voltage compartments.
![]()
![]()
| Specification | Data | Specification | Data |
|---|---|---|---|
| Model | ZGSL-Z-5000(6250-7000)/34.5/0.48 | Rated Capacity | 5000/6250/7000kVA |
| Primary Voltage | 34500Y/19920V (8-Tap: 34.5kV–12.47kV) | Secondary Voltage | 480V Delta |
| Phase | Three-phase | Frequency | 60Hz |
| Vector Group | YNd1 | Primary and Secondary BIL | 150kV / 30kV |
| Temperature Rise | 55°C / 65°C / 65°C | Standard | ANSI C57.12.34 & DOE 2016 |
| Specification | Data | Specification | Data |
|---|---|---|---|
| Mounting | Pad-mounted | Use Condition | Indoor / Outdoor |
| Insulating Fluid | Mineral oil (Non-PCB) | Cooling Class | ONAN / ONAF |
| Winding Material | Aluminum | Core Form | Three-phase three-column |
| Enclosure Color | Munsell Bell Green | Altitude | ≤1000m |
| Oil Weight | 5831 lbs (784 gals on drawing) | Total Weight | 26625 lbs |
| Specification | Data | Specification | Data |
|---|---|---|---|
| No-Load Loss | 4115W | Load Loss at 85°C | 34756W |
| Short-Circuit Impedance at 85°C | 6.05% | No-Load Current | 0.16% |
General assembly drawing with outline layout, pad opening dimensions (83.0 × 31.4 in), and HV/LV bushing locations for model ZGSL-Z-5000(6250-7000)/34.5/0.48.
![]()
Standard factory-configured components, switching and protection devices, cooling hardware, and gauges on the 5000/6250/7000kVA pad-mounted transformer.
-
HV Interface & Tap Switching: Three 35kV 600A HV bushings, a 2-position loadbreak switch, an 8-step tap changer (34500V–12470V), an H0 bushing with bond strap, and three parking stands for medium-voltage connection, 8-tap voltage adjustment, and cable support.
-
Under-Oil Surge Arresters: Three 36kV MOV arresters with disconnectors for overvoltage protection and fault isolation.
-
LV 20-Hole Terminations: Three 20-hole XTG2-1/9000 LV bushings with a stainless steel ground pad for high-current 480V terminations and grounding.
-
ONAF Cooling Fans: Two 3-phase 480V fans (fed from X1-X2-X3) and a fan control box for forced-air cooling up to 7000kVA.
-
Gauges & Tank Hardware: Pressure, oil level, and oil temperature gauges, relief/drain/sampler valves, HV/LV barrier rib, lifting/grounding lugs and pads, door handle, and Munsell Bell Green finish for monitoring, maintenance, lifting/earthing, and outdoor durability.
| Specification | Available Options | Specification | Available Options |
|---|---|---|---|
| Capacity Range | 45–5000kVA | Maximum Capacity | Up to 10MVA on request |
| Typical Ratings | 75, 150, 225, 300, 500, 750, 1000, 1500, 2000, 2500, 3000kVA | Frequency | 50Hz / 60Hz |
| Primary Voltage | 12.47kV, 13.2kV, 13.8kV, 24.94kV, 34.5kV, or custom | Secondary Voltage | 208Y/120V, 480Y/277V, 600Y/347V, 240V, 480V, 600V, or custom |
| Primary BIL | 60–200kV | Feed Type | Loop Feed / Radial Feed |
| Winding Connection | Delta–Wye, Grounded Wye–Wye, Delta–Delta, Wye–Wye, or custom | Cooling Method | ONAN / ONAF / KNAN |
| HV Terminations | 200A Loadbreak, 600A Deadbreak, or Live-Front Porcelain Bushings | Tap Changer | DETC |
| Winding Material | Copper / Aluminum | Insulating Fluid | Mineral Oil / Natural Ester |
Applicable Standards: ANSI/IEEE C57 Series, CSA, DOE, and NEMA, as applicable
Certification: UL/cUL File E536138
This 5000/6250/7000kVA three-phase pad-mounted transformer steps down medium-voltage feeders to 480V Delta power for heavy commercial, industrial, and utility installations requiring multi-voltage tap flexibility and ONAF cooling capacity.
-
Multi-Voltage Utility & Substation Feeders: Supports systems operating across or transitioning between 12.47kV–34.5kV primary voltages using the 8-position off-circuit tap changer.
-
Heavy Industrial & Manufacturing Facilities: Supplies high-current 480V three-phase loads with 5000kVA/6250kVA natural cooling and up to 7000kVA forced-air cooling during peak demand.
-
Commercial Complexes, Campuses & Contractor Fleets: Fits indoor or outdoor pad installations requiring ANSI C57.12.34 compliance, UL Listing, and 20-hole LV busbar terminations.
![]()
Three-Phase Pad-Mounted Transformers
- 3 Phase Pad Mounted Transformer 2550kVA 34.5KV To 480V Oil Immersed Power Transformer UL Listed
- 3750kVA Three Phase Pad Mounted Distribution Transformer 12870V To 480Y/277V ANSI IEEE Standards
- 5 MVA 3 Phase Pad Mounted Transformer 13800V To 4160Y/2400V ANSI IEEE Standards
A: Winley delivers standard three-phase pad-mounted transformers with a 4–6 weeks production time after technical approval. We provide a detailed production schedule and real-time manufacturing photos to help track progress.
A: We offer a flexible MOQ of just 1 unit.
Complete inquiries are quoted within 1–2 days with 24/7 support. Leveraging our extensive North American project experience, we ensure highly cost-effective and reliable solutions.
A: Yes, We accept OEM and ODM. Winley three-phase pad-mounted transformers are available in standard ratings from 45–5000kVA (and maximum capability up to 10 MVA), with HV systems up to 34.5 kV. We can customize electrical parameters, structure, fluid, protection, switches, gauges, tank and paint according to customer drawings, with the capability to integrate components from brands like Qualitrol, Eaton Cooper, and MR.
A: Yes. Our full range of products are UL/cUL-certified under UL File No. E536138, designed strictly in compliance with ANSI/IEEE, CSA, DOE, and NEMA requirements to meet grid connection and regulatory standards.
A: We deliver a complete compliance package: approval drawings, datasheets, routine test reports, UL/cUL certs, DOE 2016 docs, and operation manuals. We also back your project with lifetime documentation support.
A: Winley ensures quality through 4 annual unannounced UL audits and strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).
A: 24 months from the B/L date, extendable up to 5 years upon request. During the warranty period, we provide free replacement parts upon receiving photos of any damaged accessories, include free spare parts based on order volume, and offer ongoing technical support.