3000kVA Three Phase Pad Mounted Isolation Transformer 480V to 416Y/240V FR3 KNAN ANSI/IEEE Standards
| Brand Name: | WINLEY |
| Model Number: | ZGS11-1500/0.48/0.416 |
| MOQ: | 1unit |
| Price: | $1000-$100000 |
| Packaging Details: | Plywood case |
| Payment Terms: | T/T |
- Winley Electric three-phase transformers are UL/cUL Listed under File No. E536138, with ratings from 45 kVA through 10 MVA. They are designed and manufactured to meet applicable ANSI/IEEE, CSA, NEMA, and DOE 2016 requirements.
- With extensive experience in North American utility, industrial, and commercial projects, Winley Electric can deliver cost-effective customized solutions based on your specific project requirements.
- With a strong supply chain and experienced production team, Winley Electric support fast delivery with a 4–6 weeks production time after technical approval to help keep your project on schedule.
Engineered to bridge standard 480V delta supplies with 416Y/240V grounded-wye systems, this 3000kVA three-phase pad-mounted isolation transformer provides reliable outdoor power distribution for industrial plants, data centers and critical infrastructure. Built in accordance with ANSI C57.12.34, it uses FR3 natural ester fluid and KNAN natural cooling for efficient operation without forced-air cooling equipment. The transformer provides a practical localized voltage-matching solution for manufacturing facilities and commercial campuses integrating imported or specialized 416/240V equipment into existing 480V systems.
The Dyn1 connection provides electrical isolation and establishes a grounded neutral point on the secondary side. By supplying both 416V three-phase power and 240V line-to-neutral service from a single pad-mounted unit, it can reduce the need for separate auxiliary transformers, helping simplify downstream distribution, save installation space and control overall system costs.
| Specification | Data | Specification | Data |
|---|---|---|---|
| Product Type | Three-Phase Pad-Mounted Isolation Transformer | Model | ZGS11-3000/0.48/0.416 |
| Rated Capacity | 3000kVA | Phase | 3 |
| Primary Voltage | 480V Delta | Secondary Voltage | 416Y/240V |
| Rated Frequency | 60Hz | Vector Group | Dyn1 |
| Specification | Data | Specification | Data |
|---|---|---|---|
| Cooling Method | KNAN | InsulatinWinding | Copper |
| HV BIL / LV BIL | 30kV / 30kV | Temperature Rise | 65°C |
| Overall Dimensions | 121 W × 92 D × 75 H in | Total Weight | 13,240 lb |
| Test Item | Tested Value | Test Item | Tested Value |
|---|---|---|---|
| No-Load Loss | 2,229 W | No-Load Current | 0.12% |
| Load Loss at 85°C | 24,365 W | Short-Circuit Impedance | 5.80% |
- HV and LV Bushings — Three primary and four secondary bushings are fitted with 8-hole spade terminals and 30kV BIL for high-current cable connections.
- Oil Level Gauge with Contacts — Provides local oil-level indication and electrical contacts for remote status signaling.
- Vacuum Pressure Gauge — Displays the internal pressure or vacuum condition of the sealed transformer tank.
- Pressure Relief Valve — Relieves abnormal internal tank pressure to help protect the transformer tank and seals.
- Oil Temperature Gauge with Contacts — Monitors insulating-fluid temperature and provides contacts for alarm or control signals.
- Gas Sampler Valve — Allows gas sampling for inspection and insulation-condition assessment.
- Oil Fill Plug and Drain Valve — Supports oil filling, filtering, sampling and complete oil drainage during maintenance.
- Grounding Pads and Lugs — Provides grounding points for the tank, neutral conductor and protective grounding system.
- Sector: Industrial Manufacturing
Suitable applications:
High-end manufacturing facilities integrating automated production lines, process skids, cleanrooms, or European/Asian imported machinery specified for 415V/416V power into an existing 480V plant infrastructure.
Why this transformer fits:
The 480V to 416Y/240V transformation provides localized, isolated power for both major 416V motors and 240V secondary control loops out of a single compact 3000kVA installation.
- Sector: Data Centers and Critical-Power Facilities
Suitable applications:
Tier-certified data centers, enterprise server farms, and medical infrastructure deploying 415V/240V-class high-efficiency UPS topologies, power distribution units (PDUs), and server racks where incoming utility feed remains 480V.
Why this transformer fits:
The Dyn1 vector provides an electrically isolated, clean secondary wye with a robust zero-sequence path to manage harmonic loads, while the 3000kVA rating smoothly scales to high-density downstream compute requirements.
- Sector: Commercial and Institutional Campuses
Suitable applications:
Large-scale corporate campuses, multi-tenant mixed-use commercial properties, diagnostic laboratories, and research universities requiring localized 416Y/240V infrastructure stepped down from a centralized 480V loop.
Why this transformer fits:
The rugged, outdoor pad-mounted configuration safely keeps high-capacity voltage transformation hardware outside occupied building zones, reclaiming valuable interior square footage.
- Sector: Infrastructure and Process Facilities
Suitable applications:
Water/wastewater treatment utilities, chemical process facilities, and massive logistics hubs implementing pre-packaged electrical equipment and pumps engineered for 416V operation.
Why this transformer fits:
Fire-safe FR3 fluid combined with heavy-duty exterior construction, removable radiators, and fanless natural cooling ensures uninterrupted, long-life operation in remote or specialized equipment pads.
| Rated Power (KVA) |
High Voltage (KV) |
Low Voltage (V) |
No-load Loss (W) |
On-load Loss (W) |
Height (mm) |
Depth (mm) |
Width (mm) |
Weight (kg) |
Weight (Lbs) |
|---|---|---|---|---|---|---|---|---|---|
| 75KVA | 34.5KV 4.160KV 12.47KV 13.2KV 13.8KV 24940GrdY/14400 1247Grdy/7200 4160GrdY/2400 or others |
277V 347V 480V 600V 120/240V 208GrdY/120 415GrdY/240 480GrdY/277 600Y/347 |
180 | 1250 | 1430 | 910 | 1930 | 645 | 1422 |
| 150KVA | 280 | 2200 | 1530 | 980 | 1510 | 989 | 2180 | ||
| 300KVA | 480 | 3650 | 1680 | 1080 | 1660 | 1415 | 3119 | ||
| 500KVA | 680 | 5100 | 1790 | 1160 | 1810 | 1905 | 4200 | ||
| 750KVA | 980 | 7500 | 2030 | 1300 | 2030 | 2755 | 6074 | ||
| 1000KVA | 1150 | 10300 | 1854 | 1549 | 1651 | 3235 | 7132 | ||
| 1500KVA | 1640 | 14500 | 2150 | 1570 | 2210 | 5835 | 12864 | ||
| 2000KVA | 2160 | 20645 | 2220 | 1600 | 2380 | 6430 | 14175 | ||
| 2500KVA | 2680 | 23786 | 2330 | 1650 | 3070 | 8865 | 19544 | ||
| 3000KVA | 3300 | 30300 | 2460 | 1850 | 3260 | 11300 | 24912 | ||
| 3735KVA | 4125 | 37875 | 2680 | 2060 | 4080 | 14400 | 31746 |
A: Winley delivers standard three-phase pad-mounted transformers with a 4–6 weeks production time after technical approval. We provide a detailed production schedule and real-time manufacturing photos to help track progress.
A: We offer a flexible MOQ of just 1 unit. Complete inquiries are quoted within 1–2 days with 24/7 support. Leveraging our extensive North American project experience, we ensure highly cost-effective and reliable solutions.
A: Yes, We accept OEM and ODM. Winley three-phase pad-mounted transformers are available in standard ratings from 45–5000kVA (and maximum capability up to 10MVA), with HV systems up to 36 kV. We can customize electrical parameters, structure, fluid, protection, switches, gauges, tank and paint according to customer drawings, with the capability to integrate components from brands like Qualitrol, Eaton Cooper, and MR.
A: Yes. Our full range of products are UL/cUL-certified under UL File No. E536138, designed strictly in compliance with ANSI/IEEE, CSA, DOE, and NEMA requirements to meet grid connection and regulatory standards.
A: We deliver a complete compliance package: approval drawings, datasheets, routine test reports, UL/cUL certs, DOE 2016 docs, and operation manuals. We also back your project with lifetime documentation support.
A: Winley ensures quality through 4 annual unannounced UL audits and strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).
A: 24 months from B/L. During the warranty period, If there are any accessory problems, just provide photos of damaged accessory, then we will provide free service. According to the number of products, we will provide easily damaged accessories for free. We can also provide technical support if you need.