| Brand Name: | WINLEY |
| Model Number: | ZGS-2500/12.47 |
| MOQ: | 1unit |
| Price: | $5000-$150000 |
| Packaging Details: | Plywood case |
| Payment Terms: | T/T |
304 Stainless Steel Tank 2500Kva Three Phase Pad Mounted Transformer 12.47KV To 480V Power Distribution Transformer 304SS UL Listed
Overview
Introducing Winley’s 2500 kVA pad‑mounted, loop‑feed transformer — engineered for reliable utility and industrial power distribution. Built to meet ANSI C57.12.00 standards and available for indoor or outdoor service, this model combines robust electrical performance with a corrosion‑resistant 304 stainless‑steel housing and full UL/cUL certification to ensure safety, durability, and code compliance.
![]()
![]()
![]()
Main data
| No. | Particulars | Unit | Specification |
| 1 | Type | ~ | pad mounted,loop feed |
| 2 | Rated capacity | kVA | 2500 |
| 3 | No. of Phase | ~ | 3 |
| 4 | Primary voltage | V | 12470Y/7200 |
| 5 | Primary termintion | ~ | 15kV class, 200A well&insert with elbow |
| 6 | Secondary voltage | V | 480 |
| 7 | Secondary termintion | ~ | 12-hole spade |
| 8 | Tapping type | ~ | off-circuit tapping |
| 9 | Tapping range | % | ±2*2.5% |
| 10 | Cooling method | ~ | ONAN |
| 11 | Rated frequency | Hz | 60 |
| 12 | Vector group | ~ | YNd1 |
| 13 | Insulation class | ~ | A |
| 14 | Temperature rise | K | 65 |
| 15 | Off-load loss | W | 2670 |
| 16 | On-load loss (85℃) | W | 23400 |
| 17 | Impedance | % | 5.75~7.50 |
| 18 | Winding material | ~ | Aluminum |
| 19 | Core material | ~ | silicon steel |
| 20 | Cooling material | mineral oil | |
| 21 | Housing material | ~ | 304 stainless steel |
| 22 | Service condition | ~ | indoor or outdoor |
| 23 | Dimension | mm | 2950*2165*1900 |
| 24 | Weight | kg | 5514 |
| 25 | Sea level | M | ≤1000 |
Technical drawings
![]()
Benefits of 304 stainless steel fuel tanks
![]()
![]()
Why choose us
WINLEY manufactures a full range of three-phase pad-mounted transformers with capacities from 45 kVA to 5500 kVA and voltages up to 34.5 kV. The products meet or exceed DOE 2016, IEEE/ANSI, CSA, IEC, NEMA and other standards. Additionally, WINLEY’s three-phase pad-mounted transformers are UL/cUL certified (Certificate Numbers: UL‑US‑2431836‑0, UL‑CA‑2423202‑0)
![]()
Specification
| Rated Power (KVA) |
High Voltage (KV) |
Low Voltage (V) |
No-load Loss (W) |
On-load Loss (W) |
Height (mm) |
Depth (mm) |
Width (mm) |
Weight (kg) |
Weight (Lbs) |
| 75KVA | 34.5KV 4.160KV 12.47KV 13.2KV 13.8KV 24940GrdY/14400 1247Grdy/7200 4160GrdY/2400 or others |
277V 347V 480V 600V 120/240V 208GrdY/120 415GrdY/240 480GrdY/277 600Y/347 |
180 | 1250 | 1430 | 910 | 1930 | 645 | 1422 |
| 150KVA | 280 | 2200 | 1530 | 980 | 1510 | 989 | 2180 | ||
| 300KVA | 480 | 3650 | 1680 | 1080 | 1660 | 1415 | 3119 | ||
| 500KVA | 680 | 5100 | 1790 | 1160 | 1810 | 1905 | 4200 | ||
| 750KVA | 980 | 7500 | 2030 | 1300 | 2030 | 2755 | 6074 | ||
| 1000KVA | 1150 | 10300 | 1854 | 1549 | 1651 | 3235 | 7132 | ||
| 1500KVA | 1640 | 14500 | 2150 | 1570 | 2210 | 5835 | 12864 | ||
| 2000KVA | 2160 | 20645 | 2220 | 1600 | 2380 | 6430 | 14175 | ||
| 2500KVA | 2680 | 23786 | 2330 | 1650 | 3070 | 8865 | 19544 | ||
| 3000KVA | 3300 | 30300 | 2460 | 1850 | 3260 | 11300 | 24912 | ||
| 3735KVA | 4125 | 37875 | 2680 | 2060 | 4080 | 14400 | 31746 |
Production process
![]()
![]()
|
| Brand Name: | WINLEY |
| Model Number: | ZGS-2500/12.47 |
| MOQ: | 1unit |
| Price: | $5000-$150000 |
| Packaging Details: | Plywood case |
| Payment Terms: | T/T |
304 Stainless Steel Tank 2500Kva Three Phase Pad Mounted Transformer 12.47KV To 480V Power Distribution Transformer 304SS UL Listed
Overview
Introducing Winley’s 2500 kVA pad‑mounted, loop‑feed transformer — engineered for reliable utility and industrial power distribution. Built to meet ANSI C57.12.00 standards and available for indoor or outdoor service, this model combines robust electrical performance with a corrosion‑resistant 304 stainless‑steel housing and full UL/cUL certification to ensure safety, durability, and code compliance.
![]()
![]()
![]()
Main data
| No. | Particulars | Unit | Specification |
| 1 | Type | ~ | pad mounted,loop feed |
| 2 | Rated capacity | kVA | 2500 |
| 3 | No. of Phase | ~ | 3 |
| 4 | Primary voltage | V | 12470Y/7200 |
| 5 | Primary termintion | ~ | 15kV class, 200A well&insert with elbow |
| 6 | Secondary voltage | V | 480 |
| 7 | Secondary termintion | ~ | 12-hole spade |
| 8 | Tapping type | ~ | off-circuit tapping |
| 9 | Tapping range | % | ±2*2.5% |
| 10 | Cooling method | ~ | ONAN |
| 11 | Rated frequency | Hz | 60 |
| 12 | Vector group | ~ | YNd1 |
| 13 | Insulation class | ~ | A |
| 14 | Temperature rise | K | 65 |
| 15 | Off-load loss | W | 2670 |
| 16 | On-load loss (85℃) | W | 23400 |
| 17 | Impedance | % | 5.75~7.50 |
| 18 | Winding material | ~ | Aluminum |
| 19 | Core material | ~ | silicon steel |
| 20 | Cooling material | mineral oil | |
| 21 | Housing material | ~ | 304 stainless steel |
| 22 | Service condition | ~ | indoor or outdoor |
| 23 | Dimension | mm | 2950*2165*1900 |
| 24 | Weight | kg | 5514 |
| 25 | Sea level | M | ≤1000 |
Technical drawings
![]()
Benefits of 304 stainless steel fuel tanks
![]()
![]()
Why choose us
WINLEY manufactures a full range of three-phase pad-mounted transformers with capacities from 45 kVA to 5500 kVA and voltages up to 34.5 kV. The products meet or exceed DOE 2016, IEEE/ANSI, CSA, IEC, NEMA and other standards. Additionally, WINLEY’s three-phase pad-mounted transformers are UL/cUL certified (Certificate Numbers: UL‑US‑2431836‑0, UL‑CA‑2423202‑0)
![]()
Specification
| Rated Power (KVA) |
High Voltage (KV) |
Low Voltage (V) |
No-load Loss (W) |
On-load Loss (W) |
Height (mm) |
Depth (mm) |
Width (mm) |
Weight (kg) |
Weight (Lbs) |
| 75KVA | 34.5KV 4.160KV 12.47KV 13.2KV 13.8KV 24940GrdY/14400 1247Grdy/7200 4160GrdY/2400 or others |
277V 347V 480V 600V 120/240V 208GrdY/120 415GrdY/240 480GrdY/277 600Y/347 |
180 | 1250 | 1430 | 910 | 1930 | 645 | 1422 |
| 150KVA | 280 | 2200 | 1530 | 980 | 1510 | 989 | 2180 | ||
| 300KVA | 480 | 3650 | 1680 | 1080 | 1660 | 1415 | 3119 | ||
| 500KVA | 680 | 5100 | 1790 | 1160 | 1810 | 1905 | 4200 | ||
| 750KVA | 980 | 7500 | 2030 | 1300 | 2030 | 2755 | 6074 | ||
| 1000KVA | 1150 | 10300 | 1854 | 1549 | 1651 | 3235 | 7132 | ||
| 1500KVA | 1640 | 14500 | 2150 | 1570 | 2210 | 5835 | 12864 | ||
| 2000KVA | 2160 | 20645 | 2220 | 1600 | 2380 | 6430 | 14175 | ||
| 2500KVA | 2680 | 23786 | 2330 | 1650 | 3070 | 8865 | 19544 | ||
| 3000KVA | 3300 | 30300 | 2460 | 1850 | 3260 | 11300 | 24912 | ||
| 3735KVA | 4125 | 37875 | 2680 | 2060 | 4080 | 14400 | 31746 |
Production process
![]()
![]()