2/2.667MVA Dual-Rating Capacity Three Phase VPI Dry Type Transformer 6900V to 480Y/277V DOE 2016 ANSI/IEEE Standards
| Nome da marca: | WINLEY |
| Número do modelo: | SG-2000/6.9 |
| Quantidade mínima: | 1 unidade |
| Preço: | $1000-$100000 |
| Detalhes da embalagem: | caixa de madeira compensada |
| Condições de pagamento: | T/T |
Product Overview
This 2/2.667 MVA VPI dry type transformer steps 6900V Delta down to 480Y/277V Wye-N for medium-voltage facility distribution. The AN/AF rating supports 2 MVA self-cooled operation and 2.667 MVA fan-assisted capacity, helping the unit handle normal loads and peak demand in one configuration.
Built with a NEMA 3R pad/floor mount enclosure, copper windings, Dyn11 vector group, 5-position de-energized taps and LV winding temperature-controlled fans, this transformer is suitable for commercial buildings, industrial plants, outdoor electrical rooms and facility power systems requiring stable 480Y/277V distribution.
Why choose us
1. Winley Electric three-phase dry-type transformers are UL/cUL Listed under File No. E531446. UL-certified Class C insulation systems are also available under File No. E531317 to support North American project compliance and operation.
2. With experience in North American utility, industrial, commercial, solar PV, data center, and infrastructure projects, Winley Electric designs VPI dry-type transformers to meet applicable ANSI/IEEE, UL, CSA, NEMA, DOE, and related project requirements.
3. Backed by mature VPI manufacturing processes and flexible engineering design capabilities, Winley Electric VPI dry-type transformers are designed for high mechanical strength, strong overload capability, thermal endurance, and reliable operation.
![]()
Product Photos
![]()
![]()
![]()
Main Data
| Item | Data |
|---|---|
| Product type | Vacuum Pressure Impregnated dry type transformer |
| Model | SG-2000/6.9 |
| Rated capacity | 2000/2667 kVA |
| Phase | Three phase |
| Primary voltage | 6900V |
| Secondary voltage | 480Y/277V |
| Frequency | 60Hz |
| Vector group | Dyn11 |
| HV BIL / LV BIL | 60 kV / 30 kV |
| Cooling method | AN/AF |
| Winding material | Copper |
| Temperature rise | 115°C |
| Insulation class | Class F, 155°C |
| Tap changer | 5-position de-energized manual tap changer |
| Tap voltages | 7245 / 7073 / 6900 / 6728 / 6555V |
| No-load loss | 2507W |
| Load loss | 13660W at 145°C |
| Short-circuit impedance | 5.65% at 115°C |
| No-load current | 0.29% |
| Efficiency | 99.36% |
| Dimensions | 96.5"L × 66.9"W × 92.5"H |
| Weight | 11740 lbs |
Technical drawings
![]()
Standard Features
- Upper Clamping Beam
Secures the core and coils against vibration and movement. - Insulating Support Blocks
Provides support and insulation. - Three-Phase Windings
Transfers electrical energy through electromagnetic induction. - Laminated Iron Core
Provides the magnetic path and reduces core losses. - LV Busbar
Collects and delivers LV current. - LV Phase Terminals
Connects three-phase LV output cables or busbars. - Lifting Lugs
Provides lifting points for handling and installation. - Insulation Air Ducts
Provides cooling air gaps and insulation support. - Lower Clamping Beam
Clamps the core and coils in place. - Bottom Base Frame
Supports the transformer and allows installation fixing.
![]()
-
Commercial Buildings
Suitable for commercial facilities requiring 6900V to 480Y/277V power distribution, such as building service entrances, HVAC systems, lighting panels and low-voltage switchgear. -
Light Industrial Facilities
The 2/2.667 MVA AN/AF capacity supports plant distribution, workshop power supply, production equipment and auxiliary facility loads where both normal load and peak demand need to be considered. -
Outdoor Electrical Rooms
With a NEMA 3R pad/floor mount enclosure, the transformer is suitable for outdoor or semi-outdoor electrical rooms where oil-free dry type equipment is preferred. -
Facility Power Distribution Systems
The 480Y/277V secondary output can supply common North American facility loads, including lighting, HVAC, panels, motors and downstream distribution equipment. -
Data Center and Critical Facility Support
LV winding temperature sensors, fan control, alarm and trip contacts make the transformer suitable for controlled power environments where thermal monitoring and load stability are important. -
Campus and Infrastructure Projects
Suitable for campus buildings, public facilities and infrastructure power rooms requiring medium-voltage step-down to 480Y/277V distribution.
| Model (kVA) | Primary Voltage | Secondary Voltage | Coupling Group | Shape Dimension | Mounting Dimension | Box Dimension |
|---|---|---|---|---|---|---|
| SG-10KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 360×180×305 | 215×140 | 450×360×480 |
| SG-15KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 360×200×335 | 215×155 | 450×360×480 |
| SG-20KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 420×210×350 | 250×170 | 490×400×540 |
| SG-30KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 420×230×380 | 250×190 | 490×400×540 |
| SG-50KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 680×350×550 | 420×220 | 800×510×840 |
| SG-80KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 750×400×620 | 480×250 | 850×510×840 |
| SG-100KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 780×420×650 | 500×250 | 900×550×890 |
![]()