150kVA Three Phase Dry Type Isolation Transformer 600V to 208Y/120V Aluminum Windings NEMA 3R Enclosure UL/cUL Listed
| Nazwa marki: | WINLEY |
| Numer modelu: | SG-150KVA |
| MOQ: | 1 jednostka |
| Cena: | $1000-$100000 |
| Szczegóły opakowania: | Obudowa ze sklejki |
| Warunki płatności: | T/T |
Product Overview
Designed for commercial buildings, light industrial facilities and retrofit electrical rooms, this 150kVA three phase dry type isolation transformer converts 600V Delta primary power to 208Y/120V Wye-N secondary distribution. The secondary configuration supports both 208V three-phase equipment and 120V line-to-neutral branch circuits, making it suitable for facility power distribution, equipment panels and building service applications.
Built with a NEMA 3R enclosure, ANN cooling, aluminum windings and a 220°C insulation class, the transformer is suitable for indoor or sheltered installation points where dry-type, oil-free equipment is preferred. The primary tap range from 630V to 540V helps match site voltage conditions while maintaining practical flexibility for North American low-voltage distribution projects.
Why choose us
1. Winley Electric three-phase dry-type transformers are UL/cUL Listed under File No. E531446. UL-certified Class C insulation systems are also available under File No. E531317 to support North American project compliance and operation.
2. With experience in North American utility, industrial, commercial, solar PV, data center, and infrastructure projects, Winley Electric designs VPI dry-type transformers to meet applicable ANSI/IEEE, UL, CSA, NEMA, DOE, and related project requirements.
3. Backed by mature VPI manufacturing processes and flexible engineering design capabilities, Winley Electric VPI dry-type transformers are designed for high mechanical strength, strong overload capability, thermal endurance, and reliable operation.
![]()
Product Photos
![]()
![]()
![]()
Main Data
| Item | Data |
|---|---|
| Product type | Three phase dry type isolation transformer |
| Rated capacity | 150 kVA |
| Phase | Three phase |
| Primary voltage | 600V |
| Secondary voltage | 208Y/120V |
| Frequency | 60 Hz |
| Vector group | D/yn |
| Enclosure | NEMA 3R |
| Cooling method | AN |
| Winding material | AL |
| Insulation class | 220°C |
| Temperature rise | 150°C |
| No-load loss | 186.1 W |
| Load loss | 3757.1 W |
| Impedance | 5.93% |
| Dimensions | 1100W × 830D × 1400H mm |
| Weight | 590 kg |
Technical drawings
![]()
Standard Features
-
Three-phase Windings
Transforms voltage through electromagnetic induction and transfers electrical energy. -
Aluminum Windings
Made with aluminum conductors to meet electrical performance requirements while helping control transformer weight and manufacturing cost. -
Laminated Iron Core
Provides a magnetic path and helps reduce eddy-current losses. -
Primary Terminal Busbar
Connects the incoming power supply to the primary windings. -
Primary Phase Terminals
Connection points for the three-phase primary input. -
Tap Terminals
Allows voltage adjustment by selecting different winding taps. -
Tap Jumper Leads
Links selected tap terminals to set the required voltage. -
Secondary Terminal Busbar
Delivers transformed power to the load or distribution equipment. -
Secondary Phase Terminals
Three-phase secondary output points for cables or busbars. -
Insulation Support
Supports terminals and busbars while maintaining electrical clearance. -
Clamping Beams
Secures the core and coils against vibration and movement. -
Base Frame
Supports the transformer body for installation and handling.
![]()
| Sector | Suitable applications |
|---|---|
| Commercial buildings | Main electrical rooms, service panels, tenant power distribution |
| Light industrial facilities | Small production lines, machinery panels, facility distribution |
| Retrofit projects | Replacement of existing 600V step-down transformers |
| Electrical rooms | Indoor dry-type transformer installation |
| Protected outdoor points | Covered or sheltered distribution locations |
| Model (kVA) | Primary Voltage | Secondary Voltage | Coupling Group | Shape Dimension | Mounting Dimension | Box Dimension |
|---|---|---|---|---|---|---|
| SG-10KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 360×180×305 | 215×140 | 450×360×480 |
| SG-15KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 360×200×335 | 215×155 | 450×360×480 |
| SG-20KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 420×210×350 | 250×170 | 490×400×540 |
| SG-30KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 420×230×380 | 250×190 | 490×400×540 |
| SG-50KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 680×350×550 | 420×220 | 800×510×840 |
| SG-80KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 750×400×620 | 480×250 | 850×510×840 |
| SG-100KVA | 660/400/380/200 | 380/220/110/36 | Yyn0/Y/d/D/y/D/d | 780×420×650 | 500×250 | 900×550×890 |
![]()