Product Overview
Single-phase pad-mounted transformers are compact, self-contained electrical units housed in secure, lockable outdoor cabinets. These transformers are oil-insulated, self-cooled, and designed with dead-front construction, available in both loop and radial feed configurations.
The single phase pad mounted transformers produced by WINLEY ELECTRIC have obtained UL/cUL certification. The products fully comply with or even exceed ANSI/IEEE, DOE, and CSA standards. The rated capacity ranges from 10KVA to 250KVA, and the primary voltage can reach 34.5kV. The monthly delivery capacity exceeds 800 units, and can be delivered quickly within 4 weeks.
Single phase pad mounted transformers has the characteristics of small size, light weight, low noise, low loss, safety and reliability.It is widely used in residential quarters, commercial centers, hospitals, parks, schools, etc.
Design Capability
Capacity | 15-333kVA |
Primary Vollage | 34.5KV/19.92KV、13.8KV/7.957KV、13.2KV/7.62KV、12.47KV/7.2KV、4160GrdY/2400V or other |
Secondary Voltage | 120/240V、240/480V、347/600V or other |
Feed Type | Loop Feed 、 Radial Feed |
Insulation Fluids | ONAN、KNAN、Envirotemp™ FR3™ |
Frequency | 50Hz、60Hz |
BIL | 30V-150V |
Standards | ANSI/IEEE C57.12.20, C5712.38, CS7.12.90 CSA C227.3 DOE NEMA |
Standard Features
Accesscries
Main Accessries | Option Accessries |
HV Bushings*2 | Multiple voltages or taps |
LV Bushings*3 | Stainless steel tank, tank bottom, sill, door, and/or hardware |
Tap Changer*1 | Service entrance in the sill |
Bay-O-Net Fuse*1 | Various spades and terminals available for secondary bushings |
ELSP Fuse*1 | High-voltage bushing inserts |
Oil Level Gauge*1 | Ground connectors |
Pressure Relief Valve*1 | One piece high-voltage bushings |
Thermomter*1 | Load break switches |
Fill Plug*1 | Drain/sampling valve |
Drain Valve*1 | Pressure vacuum gauge |
Ground Strap Copper*1 | Liquid level gauge |
Grounding Spade Terminal*2 | Temperature gauge |
Specification
Rated Capacity |
High voltage | No Load Loss | On load Loss | Height | Depth | Width | Oil Weight | Total Weight |
(kVA) | (kV) | (W) | (W) | (mm) | (mm) | (mm) | (kg) | (kg) |
15 kVA | 34.5/19.92 13.8/8 13.2/7.6 12.47/7.2 or others |
50 | 195 | 840 | 740 | 610 | 45 | 294 |
25 kVA | 80 | 290 | 840 | 740 | 610 | 68 | 362 | |
37.5 kVA | 106 | 360 | 840 | 760 | 610 | 75 | 476 | |
50 kVA | 135 | 500 | 840 | 810 | 610 | 93 | 553 | |
75 kVA | 190 | 650 | 840 | 860 | 610 | 132 | 672 | |
100 kVA | 280 | 1010 | 910 | 1200 | 965 | 230 | 714 | |
167 kVA | 435 | 1530 | 1000 | 1200 | 965 | 265 | 913 | |
250 kVA | 550 | 2230 | 1250 | 1300 | 1430 | 325 | 1106 |
Product drawings
Performance Characteristic
Testing
* Ratio, Polarity, and Phase Relation: Assures correct winding ratios and tap voltages; checks insulationof HV and LV circuits. Checks entire insulation system to verily all live-lo·ground clearances.
*Resistance: This test verifies the integrity of intemal high-voltage and low-voltage connections;provides data for loss upgrade calculations.
* Applied Potentiat: Applied lo both high-voltage and low-vollage windings, this test stresses the entireinsulation system to verify all live-to-ground clearances.
*Induced Potential: 3.46 times normal plus 1000 voits for reduced neutral designs.
* Loss Test: These design verification tesls are conducted to assure that guaranteed loss values are meland that test values are within design tolerances. Tests include no-load loss and excitation current
along with impedance voltage and load loss.
* Leak Test: Pressurizing the tank to 7 psig assures a complete seal, with no weld or gasket leaks, toeliminate the possibility of moisture infiltration or fluid oxidation.
Testing Process
More Single Phase Pad Mounted transformers
Product Overview
Single-phase pad-mounted transformers are compact, self-contained electrical units housed in secure, lockable outdoor cabinets. These transformers are oil-insulated, self-cooled, and designed with dead-front construction, available in both loop and radial feed configurations.
The single phase pad mounted transformers produced by WINLEY ELECTRIC have obtained UL/cUL certification. The products fully comply with or even exceed ANSI/IEEE, DOE, and CSA standards. The rated capacity ranges from 10KVA to 250KVA, and the primary voltage can reach 34.5kV. The monthly delivery capacity exceeds 800 units, and can be delivered quickly within 4 weeks.
Single phase pad mounted transformers has the characteristics of small size, light weight, low noise, low loss, safety and reliability.It is widely used in residential quarters, commercial centers, hospitals, parks, schools, etc.
Design Capability
Capacity | 15-333kVA |
Primary Vollage | 34.5KV/19.92KV、13.8KV/7.957KV、13.2KV/7.62KV、12.47KV/7.2KV、4160GrdY/2400V or other |
Secondary Voltage | 120/240V、240/480V、347/600V or other |
Feed Type | Loop Feed 、 Radial Feed |
Insulation Fluids | ONAN、KNAN、Envirotemp™ FR3™ |
Frequency | 50Hz、60Hz |
BIL | 30V-150V |
Standards | ANSI/IEEE C57.12.20, C5712.38, CS7.12.90 CSA C227.3 DOE NEMA |
Standard Features
Accesscries
Main Accessries | Option Accessries |
HV Bushings*2 | Multiple voltages or taps |
LV Bushings*3 | Stainless steel tank, tank bottom, sill, door, and/or hardware |
Tap Changer*1 | Service entrance in the sill |
Bay-O-Net Fuse*1 | Various spades and terminals available for secondary bushings |
ELSP Fuse*1 | High-voltage bushing inserts |
Oil Level Gauge*1 | Ground connectors |
Pressure Relief Valve*1 | One piece high-voltage bushings |
Thermomter*1 | Load break switches |
Fill Plug*1 | Drain/sampling valve |
Drain Valve*1 | Pressure vacuum gauge |
Ground Strap Copper*1 | Liquid level gauge |
Grounding Spade Terminal*2 | Temperature gauge |
Specification
Rated Capacity |
High voltage | No Load Loss | On load Loss | Height | Depth | Width | Oil Weight | Total Weight |
(kVA) | (kV) | (W) | (W) | (mm) | (mm) | (mm) | (kg) | (kg) |
15 kVA | 34.5/19.92 13.8/8 13.2/7.6 12.47/7.2 or others |
50 | 195 | 840 | 740 | 610 | 45 | 294 |
25 kVA | 80 | 290 | 840 | 740 | 610 | 68 | 362 | |
37.5 kVA | 106 | 360 | 840 | 760 | 610 | 75 | 476 | |
50 kVA | 135 | 500 | 840 | 810 | 610 | 93 | 553 | |
75 kVA | 190 | 650 | 840 | 860 | 610 | 132 | 672 | |
100 kVA | 280 | 1010 | 910 | 1200 | 965 | 230 | 714 | |
167 kVA | 435 | 1530 | 1000 | 1200 | 965 | 265 | 913 | |
250 kVA | 550 | 2230 | 1250 | 1300 | 1430 | 325 | 1106 |
Product drawings
Performance Characteristic
Testing
* Ratio, Polarity, and Phase Relation: Assures correct winding ratios and tap voltages; checks insulationof HV and LV circuits. Checks entire insulation system to verily all live-lo·ground clearances.
*Resistance: This test verifies the integrity of intemal high-voltage and low-voltage connections;provides data for loss upgrade calculations.
* Applied Potentiat: Applied lo both high-voltage and low-vollage windings, this test stresses the entireinsulation system to verify all live-to-ground clearances.
*Induced Potential: 3.46 times normal plus 1000 voits for reduced neutral designs.
* Loss Test: These design verification tesls are conducted to assure that guaranteed loss values are meland that test values are within design tolerances. Tests include no-load loss and excitation current
along with impedance voltage and load loss.
* Leak Test: Pressurizing the tank to 7 psig assures a complete seal, with no weld or gasket leaks, toeliminate the possibility of moisture infiltration or fluid oxidation.