100Kva Single Phase Pad mounted Transformer Dual Windings 12.47KV To 120V ANSI DOE
| 브랜드 이름: | WINLEY |
| 모델 번호: | ZGD-100/12.47 |
| MOQ: | 1 유닛 |
| 가격: | $1000-$10000 |
| 포장에 대한 세부 사항: | 합판 케이스 |
| 지불 조건: | t/t |
100KVA single phase pad mounted transformer
,dual windings pad mounted transformer
,ANSI DOE 12.47KV to 120V transformer
100Kva Single Phase Pad mounted Transformer Dual Windings 12.47KV To 120V ANSI DOE
Single-phase pad-mounted transformers are compact, self-contained electrical device.It has the characteristics of small size, light weight, low noise, low loss, safety and reliability.It is widely used in residential quarters, commercial centers, hospitals, parks, schools, etc.
![]()
Main data
| Transformer Type | Pad Mounted, Compartmental-Type II |
| Transformer Feed Type | Loop Feed |
| Phase | Single Phase |
| Capacity | 100 KVA |
| Vector Group | II6 |
| Primary Voltage | 12470Y/7200 |
| Secondary Voltage | 120/240V (L-N-L) |
| Secondary Voltage Class | 1.2 kV Class |
| Secondary Phasor | Dual Windings, Single Phase |
| Secondary BIL | 30 KV |
| Frequency | 60 Hz |
| Temperature Rise | 65°C |
| Cooling Class | ONAN; Self-Cooled |
| Efficiency Standard(s) | Meets DOE 2016 Standards, Meets ANSI/IEEE Standards |
| Winding Material | Aluminum |
| Ambient Temperature Rating | 40°C |
| Efficiency | 99.00% |
Key Features & Drawing
Operating at the standard 60 Hz frequency, these 100 kVA single-phase pad-mounted transformers exhibit exceptional performance. With a primary voltage rating of 12.47GrdY/7.2 kV and a secondary voltage of 240/120V, they achieve an impressive peak efficiency of 99.25%. What distinguishes them is their meticulous design, featuring a four-position load-break switch and a five-position tap changer.
![]()
![]()
Electrical Protection & Connections
- Primary connection: Dead-front design with cover-mount eyebolts; includes 200 A load-break elbows with inserts and (2) primary connections plus one standoff bracket for parked elbows
- Primary overcurrent protection: Internally mounted partial-range current-limiting fuse and draw-out load-break oil temperature-sensitive link; bayonet fuse holder with drip shield
- Primary arrestor mounting: Boss-nut provisions on H1 and H2 for lightning arrestor installation
- Secondary connections: Live-front NEMA spade terminals (8-hole spade), externally clamped, three secondary connections; secondary overcurrent protection not included
- Grounding: One grounding lug on primary and one on secondary
- Metering, auxiliary controls and load-break switches: Not included
Specification
| Single phase Pad mounted Transformer Specification | ||||||||
| Rating | High voltage(kV) | No Load Loss | On load Loss | Height | Depth | Width | Oil Weight(kg) | Total Weight(kg) |
| (kVA) | (mm) | (mm) | (mm) | |||||
| 15 kVA | 34.5/19.92 13.8/8 13.2/7.6 12.47/7.2 or others |
50 | 195 | 840 | 740 | 610 | 45 | 294 |
| 25 kVA | 80 | 290 | 840 | 740 | 610 | 68 | 362 | |
| 37.5 kVA | 106 | 360 | 840 | 760 | 610 | 75 | 476 | |
| 50 kVA | 135 | 500 | 840 | 810 | 610 | 93 | 553 | |
| 75 kVA | 190 | 650 | 840 | 860 | 610 | 132 | 672 | |
| 100 kVA | 280 | 1010 | 910 | 1200 | 965 | 230 | 714 | |
| 167 kVA | 435 | 1530 | 1000 | 1200 | 965 | 265 | 913 | |
| 250 kVA | 550 | 2230 | 1250 | 1300 | 1430 | 325 | 1106 | |