600kVA Three Phase Pad Mounted Transformer 24940V to 480Y/277V Dead Front Step Down Transformer DOE 2016 Efficiency
| Nama merek: | WINLEY |
| Nomor Model: | ZGS-Z-600/24.94/0.48 |
| MOQ: | 1 unit |
| Harga: | $1000-$100000 |
| Rincian kemasan: | kasus kayu lapis |
| Ketentuan Pembayaran: | T/T |
- Winley Electric three-phase transformers are UL/cUL Listed under File No. E536138, with ratings from 45 kVA through 7000 kVA. They are designed and manufactured to meet applicable ANSI/IEEE, CSA, NEMA, and DOE 2016 requirements.
- With extensive experience in North American utility, industrial, and commercial projects, Winley Electric can deliver cost-effective customized solutions based on your specific project requirements.
- With a strong supply chain and experienced production team, standard three-phase pad-mounted transformers can be completed in 4–6 weeks after technical approval to help keep your project on schedule.
This 600 kVA three-phase pad-mounted transformer steps 24940Y/14400V down to 480Y/277V, built in strict compliance with ANSI/IEEE C57.12.34 standards. Configured for outdoor distribution, it provides the standard voltage required for commercial facilities, light industrial plants, and utility networks. The secure, tamper-resistant enclosure supports outdoor installation near commercial buildings and public facilities while connecting to underground medium-voltage distribution systems.
The transformer uses FR3 natural ester insulating fluid with KNAN cooling to provide reliable thermal performance and enhanced fire characteristics for outdoor distribution service. Integrated primary switching, coordinated fuse protection, and five-position voltage adjustment create a compact distribution package for commercial, industrial, and utility applications requiring dependable operation and secure outdoor installation.
| Item | Data |
|---|---|
| Product Type | Three-phase liquid-filled pad-mounted distribution transformer |
| Rated Capacity | 600kVA |
| Phase | Three phase |
| Primary Voltage | 24940Y/14400V |
| Secondary Voltage | 480Y/277V |
| Rated Primary Current | 13.9A |
| Rated Secondary Current | 721.7A |
| Frequency | 60Hz |
| Vector Group | YNyn0 |
| HV/LV BIL | 125kV / 30kV |
| Cooling Method | KNAN |
| Insulating Liquid | FR3 oil, non-PCB |
| Winding Material | Copper |
| Temperature Rise | 65°C |
| No-load Loss | 875W |
| Load Loss at 85°C | 6370W |
| Impedance | 5.55% |
| Overall Dimensions | 55 × 67 × 67in, W × D × H |
| Weight | 5807lb |
- Vacuum Pressure Gauge & Pressure Relief Valve
Provides clear local indication of internal tank pressure, while the pressure relief valve releases excessive pressure to help protect tank integrity. - Liquid Level & Temperature Gauges
Provide direct dial-type indication of FR3 fluid level and operating temperature for routine inspection and condition monitoring. - Bayonet Fuse Protection
Three-phase Bayonet fuses provide primary overcurrent protection and work with current-limiting backup fuses for coordinated fault protection. - Two-Position Loadbreak Switch
Allows the transformer primary circuit to be connected or disconnected under rated load conditions, supporting convenient system operation and isolation. - Five-Position Off-Circuit Tap Changer
Provides ±2 × 2.5% primary-voltage adjustment for matching local feeder conditions and maintaining the required secondary output. - Drain Valve with Sampling Device
Located near the bottom of the tank for controlled fluid draining and convenient FR3 fluid sampling without draining the entire tank. - Comprehensive Grounding Provisions
Includes four grounding lugs and a dedicated X0 grounding pad to provide secure grounding points for the enclosure, tank, and low-voltage neutral.
-
Commercial Power Supply
Suitable Applications:
Shopping centers, office buildings, mixed-use developments, hotels, and school campuses.Why This Transformer Fits:
The 480Y/277V secondary provides a widely used North American distribution voltage for HVAC equipment, pumps, motors, lighting, and building distribution panels. Its compact pad-mounted construction allows the transformer to be installed outdoors, helping preserve valuable indoor electrical space. FR3 natural ester insulating fluid also supports commercial projects that prioritize improved fire performance and lower environmental impact. -
Light Industrial Facilities
Suitable Applications:
Manufacturing plants, assembly workshops, processing facilities, logistics centers, and warehouse distribution hubs.Why This Transformer Fits:
The 600kVA rating provides dependable capacity for motors, production equipment, material-handling systems, and facility auxiliary loads. Its liquid-filled KNAN design supports stable outdoor operation, while the enclosed steel housing protects the primary and secondary connection areas from direct contact, weather exposure, and common industrial-yard contaminants. -
Utility Distribution Points and Outdoor Networks
Suitable Applications:
Municipal underground distribution systems, suburban utility service points, commercial parks, and institutional distribution networks.Why This Transformer Fits:
Designed in accordance with ANSI/IEEE C57.12.34, the transformer follows a recognized North American standard for three-phase pad-mounted transformers. Its 24940Y/14400V primary rating, dead-front medium-voltage interfaces, loadbreak switching, and coordinated fuse protection make it well suited to underground distribution systems requiring a secure outdoor transformer installation.
| Rated Power (KVA) |
High Voltage (KV) |
Low Voltage (V) |
No-load Loss (W) |
On-load Loss (W) |
Height (mm) |
Depth (mm) |
Width (mm) |
Weight (kg) |
Weight (Lbs) |
|---|---|---|---|---|---|---|---|---|---|
| 75KVA | 34.5KV 4.160KV 12.47KV 13.2KV 13.8KV 24940GrdY/14400 1247Grdy/7200 4160GrdY/2400 or others |
277V 347V 480V 600V 120/240V 208GrdY/120 415GrdY/240 480GrdY/277 600Y/347 |
180 | 1250 | 1430 | 910 | 1930 | 645 | 1422 |
| 150KVA | 280 | 2200 | 1530 | 980 | 1510 | 989 | 2180 | ||
| 300KVA | 480 | 3650 | 1680 | 1080 | 1660 | 1415 | 3119 | ||
| 500KVA | 680 | 5100 | 1790 | 1160 | 1810 | 1905 | 4200 | ||
| 750KVA | 980 | 7500 | 2030 | 1300 | 2030 | 2755 | 6074 | ||
| 1000KVA | 1150 | 10300 | 1854 | 1549 | 1651 | 3235 | 7132 | ||
| 1500KVA | 1640 | 14500 | 2150 | 1570 | 2210 | 5835 | 12864 | ||
| 2000KVA | 2160 | 20645 | 2220 | 1600 | 2380 | 6430 | 14175 | ||
| 2500KVA | 2680 | 23786 | 2330 | 1650 | 3070 | 8865 | 19544 | ||
| 3000KVA | 3300 | 30300 | 2460 | 1850 | 3260 | 11300 | 24912 | ||
| 3735KVA | 4125 | 37875 | 2680 | 2060 | 4080 | 14400 | 31746 |
A: Winley delivers standard three-phase pad-mounted transformers with a 4–6 weeks production time after technical approval. We provide a detailed production schedule and real-time manufacturing photos to help track progress.
A: We offer a flexible MOQ of just 1 unit. Complete inquiries are quoted within 1–2 days with 24/7 support. Leveraging our extensive North American project experience, we ensure highly cost-effective and reliable solutions.
A: Yes, We accept OEM and ODM. Winley three-phase pad-mounted transformers are available in standard ratings from 45–5000kVA (and maximum capability up to 7000 kVA), with HV systems up to 36 kV. We can customize electrical parameters, structure, fluid, protection, switches, gauges, tank and paint according to customer drawings, with the capability to integrate components from brands like Qualitrol, Eaton Cooper, and MR.
A: Yes. Our full range of products are UL/cUL-certified under UL File No. E536138, designed strictly in compliance with ANSI/IEEE, CSA, DOE, and NEMA requirements to meet grid connection and regulatory standards.
A: We deliver a complete compliance package: approval drawings, datasheets, routine test reports, UL/cUL certs, DOE 2016 docs, and operation manuals. We also back your project with lifetime documentation support.
A: Winley ensures quality through 4 annual unannounced UL audits and strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).
A: 24 months from B/L. If there are any accessory problems, just provide photos of damaged accessory, then we will provide free service. According to the number of products, we will provide easily damaged accessories for free. We can also provide technical support if you need.