1500 kVA Three Phase Oil Immersed Substation Power Transformer 1 kV to 415 V ONAN AS60076 Standards
| Nama merek: | WINLEY |
| Nomor Model: | S-1500/1/0,415 |
| MOQ: | 1 unit |
| Harga: | $1000-$150000 |
| Rincian kemasan: | kasus kayu lapis |
| Ketentuan Pembayaran: | T/T |
Informasi Rinci
Tempat asal:
Cina
Sertifikasi:
AS60076
jenis:
Transformator Daya Gardu
Operasi:
Turun
Kapasitas:
1500kVA
Tegangan Primer:
1 kV
Tegangan sekunder:
415 V
Kelompok vektor:
YNyn0
Kelas Pendinginan:
ONAN
Standar:
AS60076
Waktu pengiriman:
35 hari
Menyediakan kemampuan:
500set/bulan
Deskripsi Produk
1500 kVA Three Phase Oil Immersed Substation Power Transformer 1 kV to 415 V ONAN AS60076 Standards
Product Photos
Main Data
| Item | Data |
|---|---|
| Product Type | Three-Phase Oil-Immersed Substation Power Transformer |
| Rated Capacity | 1500 kVA |
| Primary Voltage | 1000 V |
| Secondary Voltage | 415 V |
| Phase | 3 Phase |
| Frequency | 50 Hz |
| Vector Group | YNyn0 |
| Cooling Method | ONAN |
| Standard | AS60076 |
| No-load Loss | 1685 W |
| No-load Current | 0.29% |
| Load Loss | 15805 W at 85°C |
| Short-circuit Impedance | 5.48% |
| Temperature Rise | 60/55 K |
| Service Condition | Indoor or outdoor |
| Ambient Temperature | -5°C to +45°C |
| Altitude | ≤1000 m |
| Dimensions | 2550 × 1900 × 1700 mm |
| Total Weight | 4475 kg |
Technical drawings
![]()
Standard Features
| Radiator cooling assembly | Supports heat dissipation under 1500 kVA duty and helps buyers plan installation space and ventilation. |
| Radiator protection frame | Helps reduce the risk of radiator fin deformation during transport, lifting, and installation. |
| High-current LV terminal design | Helps buyers verify busbar, cable lug, and LV switchgear inlet design instead of checking voltage only. |
| Operation monitoring components | Enables operators to monitor oil level, oil temperature, and pressure status; pressure relief supports overpressure protection. |
| Drain valve / sampling arrangement | Supports future oil sampling, dielectric breakdown testing, and DGA; the tested oil DBV average value is 43.25 kV. |
| Grounding pads, lifting plates, and jacking pads | Supports grounding, lifting, positioning, and foundation installation planning. |
![]()
Applications
| Sector | Applications |
|---|---|
| Industrial | Manufacturing plants, processing lines, workshops, motor control systems, and general plant power distribution |
| Commercial | Large buildings, service facilities, shopping centers, and building electrical rooms requiring 415 V distribution |
| Infrastructure | Water treatment plants, transport facilities, utility support systems, and public-service power systems |
| Energy & Site Power | Local distribution points, site substations, equipment power supply, and project-based electrical conversion systems |
Substation Transformer Specification
| kVA | HV | LV | Width(mm) | Length(mm) | Height(mm) |
| 315kVA | 11000V | 400V | 800 | 696 | 1336 |
| 500kVA | 27600V | 480GrdY/277V | 1730 | 2300 | 1510 |
| 500kVA | 11000V | 415V | 1700 | 1700 | 1650 |
| 750kVA | 11000V | 433V | 1850 | 1845 | 1465 |
| 1000kVA | 14400V | 415/240V | 1085 | 1860 | 1570 |
| 1200kVA | 13800V | 240V | 2450 | 1850 | 1820 |
| 1500kVA | 24940V | 600V | 1800 | 1880 | 1895 |
| 2000kVA | 7200V | 600GrdY/346 | 1766 | 2680 | 1982 |
| 2000kVA | 44000V | 600V | 1260 | 2090 | 1700 |
| 2500kVA | 24940V | 480GrdY/277V | 2400 | 2200 | 2060 |
| 3000kVA | 11000V | 415V | 1600 | 2330 | 1920 |
| 3000kVA | 22800V | 415/240V | 2130 | 3500 | 1910 |
| 3750kVA | 44000V | 600V | 2240 | 2650 | 2700 |
| 4000kVA | 33kV | 600Y/347 | 2150 | 3250 | 2290 |
| 5000kVA | 34500V | 7200V | 3780 | 1850 | 3450 |
| 5000kVA | 34500V | 4160V | 2799 | 2400 | 2938 |
| 6300kVA | 35000V | 400V | 3520 | 2820 | 3470 |
| 6800kVA | 34500V | 800V | 3400 | 2670 | 3400 |
| 7500kVA | 27600Y | 4160V | 3350 | 3290 | 2270 |
![]()
![]()